C. Heising, M. Oettmeier, M. Gorski, V. Staudt, A. Steimel
{"title":"Implications of resonant circuit adjustment errors to the DC-link voltage in single-phase 16.7-Hz-railway applications","authors":"C. Heising, M. Oettmeier, M. Gorski, V. Staudt, A. Steimel","doi":"10.1109/CPE.2009.5156037","DOIUrl":null,"url":null,"abstract":"Traction vehicles operating in the single-phase 16.7-Hz-railway grid - typical for central Europe - employ a resonant circuit connected in parallel to the DC-link capacitor. The resonant circuit is necessary to take up the unavoidable grid power pulsation with double frequency, leaving a smooth DC-link voltage. In reality grid-voltage frequency and resonance frequency of the resonant circuit do not fit accurately: Manufacturing tolerances of resonant-circuit capacitor and inductance lead to an adjustment error and the railway-grid frequency moves within a defined intervall, due to the power-frequency control, independent from the European interconnected mains. In this paper implications of the adjustment error are analysed. Additionally instructions for parameter identification are given and backed by measurement results.","PeriodicalId":272748,"journal":{"name":"2009 Compatibility and Power Electronics","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-05-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"15","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 Compatibility and Power Electronics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPE.2009.5156037","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 15
Abstract
Traction vehicles operating in the single-phase 16.7-Hz-railway grid - typical for central Europe - employ a resonant circuit connected in parallel to the DC-link capacitor. The resonant circuit is necessary to take up the unavoidable grid power pulsation with double frequency, leaving a smooth DC-link voltage. In reality grid-voltage frequency and resonance frequency of the resonant circuit do not fit accurately: Manufacturing tolerances of resonant-circuit capacitor and inductance lead to an adjustment error and the railway-grid frequency moves within a defined intervall, due to the power-frequency control, independent from the European interconnected mains. In this paper implications of the adjustment error are analysed. Additionally instructions for parameter identification are given and backed by measurement results.