Implications of resonant circuit adjustment errors to the DC-link voltage in single-phase 16.7-Hz-railway applications

C. Heising, M. Oettmeier, M. Gorski, V. Staudt, A. Steimel
{"title":"Implications of resonant circuit adjustment errors to the DC-link voltage in single-phase 16.7-Hz-railway applications","authors":"C. Heising, M. Oettmeier, M. Gorski, V. Staudt, A. Steimel","doi":"10.1109/CPE.2009.5156037","DOIUrl":null,"url":null,"abstract":"Traction vehicles operating in the single-phase 16.7-Hz-railway grid - typical for central Europe - employ a resonant circuit connected in parallel to the DC-link capacitor. The resonant circuit is necessary to take up the unavoidable grid power pulsation with double frequency, leaving a smooth DC-link voltage. In reality grid-voltage frequency and resonance frequency of the resonant circuit do not fit accurately: Manufacturing tolerances of resonant-circuit capacitor and inductance lead to an adjustment error and the railway-grid frequency moves within a defined intervall, due to the power-frequency control, independent from the European interconnected mains. In this paper implications of the adjustment error are analysed. Additionally instructions for parameter identification are given and backed by measurement results.","PeriodicalId":272748,"journal":{"name":"2009 Compatibility and Power Electronics","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-05-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"15","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 Compatibility and Power Electronics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPE.2009.5156037","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 15

Abstract

Traction vehicles operating in the single-phase 16.7-Hz-railway grid - typical for central Europe - employ a resonant circuit connected in parallel to the DC-link capacitor. The resonant circuit is necessary to take up the unavoidable grid power pulsation with double frequency, leaving a smooth DC-link voltage. In reality grid-voltage frequency and resonance frequency of the resonant circuit do not fit accurately: Manufacturing tolerances of resonant-circuit capacitor and inductance lead to an adjustment error and the railway-grid frequency moves within a defined intervall, due to the power-frequency control, independent from the European interconnected mains. In this paper implications of the adjustment error are analysed. Additionally instructions for parameter identification are given and backed by measurement results.
谐振电路调整误差对单相16.7赫兹铁路直流电压的影响
在中欧典型的单相16.7赫兹铁路网中运行的牵引车辆采用与直流链路电容并联的谐振电路。谐振电路是必要的,以承担不可避免的电网功率脉动的双频,留下一个平稳的直流链路电压。在现实中,电网电压频率和谐振电路的谐振频率不能精确匹配:谐振电路电容和电感的制造公差导致调整误差,并且由于工频控制,铁路电网频率在规定的间隔内移动,独立于欧洲互联市电。本文分析了平差的含义。另外,给出了参数识别的说明,并以测量结果为依据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信