{"title":"Torsional Improvements in a Multistoried Building with Plan Irregularities","authors":"Ashish Dhakal, R. Shrestha","doi":"10.3126/jacem.v7i01.47317","DOIUrl":null,"url":null,"abstract":"Irregular buildings consist of large number of modern urban structures. Though some buildings look symmetrical in plan might have irregular distribution of mass, strength and stiffness along the plan and height of the buildings. In common sense, a building with a regular geometry is supposed to be regular building. While the building is designed to be used for different functions along the building area and along the building plan the presence of opening, staircase positioning and positioning of the shear/core wall for different purpose like lift and HVAC (Heating, Ventilation and Air Conditioning) leads to the irregularity in the plan. Ultimately, torsion irregularity occurs, which if remains not taken care properly may create substantial damage of the building structures. The purpose of this study is to determine the conditions for excessive torsional irregularity and solve them with the proper positioning of the shear wall to counter the torsional behavior of the building. A linear response analysis was conducted and the studied structures were both six- storey buildings. First building has opening left for different purpose like lift and HVAC systems. While the second building has shear wall for lift at the edge of the building. Though both buildings seem fine with their geometrical orientation after the analysis torsional irregularity was evident. The proper placement of the shear wall has been used to stiffen the building to counter for the torsional modal and make to regular in terms of the mass and stiffness distribution.","PeriodicalId":306432,"journal":{"name":"Journal of Advanced College of Engineering and Management","volume":"39 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-08-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Advanced College of Engineering and Management","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3126/jacem.v7i01.47317","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Irregular buildings consist of large number of modern urban structures. Though some buildings look symmetrical in plan might have irregular distribution of mass, strength and stiffness along the plan and height of the buildings. In common sense, a building with a regular geometry is supposed to be regular building. While the building is designed to be used for different functions along the building area and along the building plan the presence of opening, staircase positioning and positioning of the shear/core wall for different purpose like lift and HVAC (Heating, Ventilation and Air Conditioning) leads to the irregularity in the plan. Ultimately, torsion irregularity occurs, which if remains not taken care properly may create substantial damage of the building structures. The purpose of this study is to determine the conditions for excessive torsional irregularity and solve them with the proper positioning of the shear wall to counter the torsional behavior of the building. A linear response analysis was conducted and the studied structures were both six- storey buildings. First building has opening left for different purpose like lift and HVAC systems. While the second building has shear wall for lift at the edge of the building. Though both buildings seem fine with their geometrical orientation after the analysis torsional irregularity was evident. The proper placement of the shear wall has been used to stiffen the building to counter for the torsional modal and make to regular in terms of the mass and stiffness distribution.
平面图不规范的多层建筑的抗扭改善
不规则建筑由大量现代城市建筑组成。虽然有些建筑在平面上看起来是对称的,但在建筑的平面和高度上,质量、强度和刚度的分布可能是不规则的。在常识中,具有规则几何形状的建筑应该是规则建筑。虽然建筑被设计用于建筑区域和建筑平面的不同功能,但开口的存在、楼梯的定位和剪力墙/核心墙的定位,如电梯和HVAC(采暖、通风和空调)的不同用途,导致了平面的不规则性。最终,扭转不规则会发生,如果不加以妥善处理,可能会对建筑结构造成重大破坏。本研究的目的是确定过度扭转不规则的条件,并通过适当的剪力墙定位来解决这些条件,以对抗建筑物的扭转行为。进行了线性响应分析,所研究的结构均为六层建筑。第一个建筑有不同的用途,如电梯和暖通空调系统。而第二座建筑在建筑边缘有剪力墙用于升力。虽然经过分析,两栋建筑的几何方向看起来都很好,但扭转不规则性很明显。剪力墙的合理布置对结构进行了加筋,以对抗扭转模态,使结构的质量和刚度分布趋于规则。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信