SAW bioliquids sensor with RF interrogation

I. Leonte, M. Hunt, G. Sehra, M. Cole, J. Gardner
{"title":"SAW bioliquids sensor with RF interrogation","authors":"I. Leonte, M. Hunt, G. Sehra, M. Cole, J. Gardner","doi":"10.1109/HFPSC.2004.1360348","DOIUrl":null,"url":null,"abstract":"A system based on shear horizontal surface acoustic wave (SH-SAW) devices operating in the 433 MHz and 869 MHz industrial, scientific and medical (ISM) bands is proposed for wireless identification and characterisation of bioliquids. The theory of operation is briefly explained and details of the passive microsensors design and fabrication are presented. A small device antenna is analyzed and the interrogation unit implementation is discussed. A new low cost solution for measuring inter-pulse time delays with nanosecond resolution is also proposed.","PeriodicalId":405718,"journal":{"name":"High Frequency Postgraduate Student Colloquium, 2004","volume":"15 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2004-11-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"High Frequency Postgraduate Student Colloquium, 2004","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/HFPSC.2004.1360348","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

A system based on shear horizontal surface acoustic wave (SH-SAW) devices operating in the 433 MHz and 869 MHz industrial, scientific and medical (ISM) bands is proposed for wireless identification and characterisation of bioliquids. The theory of operation is briefly explained and details of the passive microsensors design and fabrication are presented. A small device antenna is analyzed and the interrogation unit implementation is discussed. A new low cost solution for measuring inter-pulse time delays with nanosecond resolution is also proposed.
带射频询问的SAW生物液体传感器
提出了一种基于工作在433 MHz和869 MHz工业、科学和医疗(ISM)频段的剪切水平表面声波(SH-SAW)设备的系统,用于生物液体的无线识别和表征。简要说明了无源微传感器的工作原理,并详细介绍了无源微传感器的设计和制造过程。分析了一种小型装置天线,讨论了讯问单元的实现。同时提出了一种低成本的纳秒级脉冲间时延测量方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信