THE INTER-RATER AND INTRA-RATER RELIABILITY OF GLENOHUMERAL JOINT POSITION AND MOVEMENT SENSE TESTS APPLIED USING AN ISOKINETIC DYNAMOMETER

S. Arslan, G. Yapali
{"title":"THE INTER-RATER AND INTRA-RATER RELIABILITY OF GLENOHUMERAL JOINT POSITION AND MOVEMENT SENSE TESTS APPLIED USING AN ISOKINETIC DYNAMOMETER","authors":"S. Arslan, G. Yapali","doi":"10.21653/tjpr.997172","DOIUrl":null,"url":null,"abstract":"Purpose: The aim of this study was to test the inter-rater and intra-rater reliability of glenohumeral joint (GHJ) position and movement sense tests of an isokinetic dynamometer in healthy individuals. \nMethods: The study included 17 healthy subjects. GHJ position and movement sense tests were applied with an isokinetic dynamometer to the dominant extremity. \nResults: The different error types calculated for position sense were in the range of mean 0.02±1.62 - 5.42±1.74. The ICC value for the different error types was determined in the range of 0.038 - 0.657 for the intra-rater tests, and 0.095 - 0.779 for the inter-rater tests. The movement sense test results for different directions and angles ranged from 9.61±2.61 to 11.18±2.89. The ICC values for movemeent sense were in the range of 0.687 – 0.912 for the intra-rater tests, and 0.844 - 0.925 for the inter-rater tests. \nConclusion: The isokinetic dynamometer showed moderate-good intra-rater and inter-rater test reliability in the measurement of the GHJ internal rotation movement sense. The intra-rater test reliability was poor in external rotation but the inter-rater test reliability was moderate-good. However in the measurement of movement sense, the isokinetic dynamometer showed intra-rater and inter-rater test reliability at an excellent level. The conformity of both the position and the movement sense tests, and therefore, the repeatability, was extremely good.","PeriodicalId":289913,"journal":{"name":"Türk Fizyoterapi ve Rehabilitasyon Dergisi","volume":"76 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-11-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Türk Fizyoterapi ve Rehabilitasyon Dergisi","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21653/tjpr.997172","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: The aim of this study was to test the inter-rater and intra-rater reliability of glenohumeral joint (GHJ) position and movement sense tests of an isokinetic dynamometer in healthy individuals. Methods: The study included 17 healthy subjects. GHJ position and movement sense tests were applied with an isokinetic dynamometer to the dominant extremity. Results: The different error types calculated for position sense were in the range of mean 0.02±1.62 - 5.42±1.74. The ICC value for the different error types was determined in the range of 0.038 - 0.657 for the intra-rater tests, and 0.095 - 0.779 for the inter-rater tests. The movement sense test results for different directions and angles ranged from 9.61±2.61 to 11.18±2.89. The ICC values for movemeent sense were in the range of 0.687 – 0.912 for the intra-rater tests, and 0.844 - 0.925 for the inter-rater tests. Conclusion: The isokinetic dynamometer showed moderate-good intra-rater and inter-rater test reliability in the measurement of the GHJ internal rotation movement sense. The intra-rater test reliability was poor in external rotation but the inter-rater test reliability was moderate-good. However in the measurement of movement sense, the isokinetic dynamometer showed intra-rater and inter-rater test reliability at an excellent level. The conformity of both the position and the movement sense tests, and therefore, the repeatability, was extremely good.
使用等速测功机进行的肩关节位置和运动感觉测试的评分间和评分内可靠性
目的:本研究的目的是检验等速测力仪在健康人群中肱骨关节(GHJ)位置和运动感觉测试的评分间和评分内的可靠性。方法:选取健康受试者17例。GHJ位置和运动感觉测试用等速测功机应用于主肢。结果:不同位置感计算误差类型的平均值在0.02±1.62 ~ 5.42±1.74之间。不同错误类型的ICC值在评级内测试的0.038 - 0.657和评级间测试的0.095 - 0.779的范围内确定。不同方向和角度的运动感觉测试结果为9.61±2.61 ~ 11.18±2.89。在评分者内部测试中,运动感觉的ICC值在0.687 - 0.912之间,在评分者之间测试中,ICC值在0.844 - 0.925之间。结论:等速测力仪在测量GHJ内旋运动感觉时,具有中佳的内、间测试信度。外旋转的内部测试信度较差,而内部测试信度为中等-良好。而在运动感觉测试中,等速测功机在测试组内和测试组间均表现出极好的信度。位置和运动感觉测试的一致性,因此,重复性,是非常好的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信