{"title":"A simple analysis of copper local loop faults in FTTB environment","authors":"A. Begovic, N. Skaljo, N. Behlilovic","doi":"10.1109/BIHTEL.2016.7775731","DOIUrl":null,"url":null,"abstract":"This paper introduces a very simple testing scenario for detecting of faults in copper local loop that remains in access network after replacing copper wires from CO (Central Office) to DP (Distribution Point) with optical fibres, i.e. after implementation of FTTB (Fibre to the Building/Basement) solution. The scenario can be useful at first for quick and quite reliable loop troubleshooting, and in particular cases for loop qualification. The first part of the paper gives a short overview of copper loop model in DSL (Digital Subscriber Line) environment, its lead testing scenarios and FTTB solution. A main steps in fault analysis and testing scenario description follow. Below that, a discussion proposed scenario usability and reliability is provided. At the end an experimental verification of the scenario, which is based on data collecting on physical system in commercial exploitation is done.","PeriodicalId":156236,"journal":{"name":"2016 XI International Symposium on Telecommunications (BIHTEL)","volume":"36 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 XI International Symposium on Telecommunications (BIHTEL)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BIHTEL.2016.7775731","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

This paper introduces a very simple testing scenario for detecting of faults in copper local loop that remains in access network after replacing copper wires from CO (Central Office) to DP (Distribution Point) with optical fibres, i.e. after implementation of FTTB (Fibre to the Building/Basement) solution. The scenario can be useful at first for quick and quite reliable loop troubleshooting, and in particular cases for loop qualification. The first part of the paper gives a short overview of copper loop model in DSL (Digital Subscriber Line) environment, its lead testing scenarios and FTTB solution. A main steps in fault analysis and testing scenario description follow. Below that, a discussion proposed scenario usability and reliability is provided. At the end an experimental verification of the scenario, which is based on data collecting on physical system in commercial exploitation is done.
FTTB环境下铜局部环路故障的简单分析
本文介绍了一个非常简单的测试场景,用于检测接入网中从CO (Central Office)到DP (Distribution Point)用光纤替换铜线后,即在实施光纤到楼/地下室(FTTB)解决方案后,仍然存在的铜本地环路故障。首先,该场景可用于快速且相当可靠的循环故障排除,在特定情况下可用于循环鉴定。本文第一部分简要介绍了DSL (Digital Subscriber Line)环境下的铜环路模型、主要测试场景和光纤到户(FTTB)解决方案。下面是故障分析和测试场景描述的主要步骤。在此之后,讨论了建议的场景可用性和可靠性。最后对基于物理系统数据采集的商业开发场景进行了实验验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信