Ryan T. Wallace, Annika M. Hansen, John A. Musser VI, Anthony P. Mai, Craig J. Chaya
{"title":"Persistent Intraocular Residue with the Use of Dexycu® in Cataract Extraction: A Case Series","authors":"Ryan T. Wallace, Annika M. Hansen, John A. Musser VI, Anthony P. Mai, Craig J. Chaya","doi":"10.9734/or/2022/v17i330258","DOIUrl":null,"url":null,"abstract":"Purpose: The objective of this article is to report 8 cases of persistent IOL residue associated with the use of Dexycu® in the context of cataract surgery and then to subsequently describe each patients clinical course. \nObservations and Presentation: Between 2020-2021, persistent residue was noted in 8 eyes of 7 patients who received Dexycu® implants after cataract surgery. The residue was identified an average of 1.63 months after surgery (range 0.20-4.23). A subsequent procedure removed the residue from the intraocular lens; the average time to the follow-up procedure after surgery was 4.71 months (range 1.90-11.20). \nConclusions and Importance: The Bausch and Lomb intraocular lenses seem to be predisposed to a Dexycu® persistent opacification, however correlation does not equate with causation. This article documents cases of persistent IOL residue with the use of Dexycu® and the MX60 lenses and its toric varieties. Further evaluation is necessary to elucidate the mechanism and risk factors for this occurrence.","PeriodicalId":287685,"journal":{"name":"Ophthalmology Research: An International Journal","volume":"40 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-08-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ophthalmology Research: An International Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.9734/or/2022/v17i330258","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: The objective of this article is to report 8 cases of persistent IOL residue associated with the use of Dexycu® in the context of cataract surgery and then to subsequently describe each patients clinical course.
Observations and Presentation: Between 2020-2021, persistent residue was noted in 8 eyes of 7 patients who received Dexycu® implants after cataract surgery. The residue was identified an average of 1.63 months after surgery (range 0.20-4.23). A subsequent procedure removed the residue from the intraocular lens; the average time to the follow-up procedure after surgery was 4.71 months (range 1.90-11.20).
Conclusions and Importance: The Bausch and Lomb intraocular lenses seem to be predisposed to a Dexycu® persistent opacification, however correlation does not equate with causation. This article documents cases of persistent IOL residue with the use of Dexycu® and the MX60 lenses and its toric varieties. Further evaluation is necessary to elucidate the mechanism and risk factors for this occurrence.