{"title":"Sequential PMU placement to monitor power flow in integrated power systems","authors":"Charu Sharma, B. Tyagi","doi":"10.1109/TDC.2014.6863180","DOIUrl":null,"url":null,"abstract":"In this paper a new approach for sequential placement of phasor measurement unit (PMU) has been proposed to monitor the power flow in transmission lines. The proposed approach is based on the real power flows and load demand in the system. Real power flow patterns at a given load have been determined using the load flow technique. As power system is continuously subjected to load variations, various load flow patterns have been obtained by increasing load at every bus. From different flow patterns different flow coverage matrices have been generated under a fixed flow coverage criterion. These flow coverage matrices have been utilized to determine the bus which covers the maximum demand of the system. The bus which covers maximum demand for various flow patterns has been selected for PMU placement. Sequential placement of PMU is considered with gradual increment in number of PMUs till whole demand of the system is covered. The proposed PMU placement technique has been tested on IEEE-14 and New England-39 bus system.","PeriodicalId":161074,"journal":{"name":"2014 IEEE PES T&D Conference and Exposition","volume":"12 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-04-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 IEEE PES T&D Conference and Exposition","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TDC.2014.6863180","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

In this paper a new approach for sequential placement of phasor measurement unit (PMU) has been proposed to monitor the power flow in transmission lines. The proposed approach is based on the real power flows and load demand in the system. Real power flow patterns at a given load have been determined using the load flow technique. As power system is continuously subjected to load variations, various load flow patterns have been obtained by increasing load at every bus. From different flow patterns different flow coverage matrices have been generated under a fixed flow coverage criterion. These flow coverage matrices have been utilized to determine the bus which covers the maximum demand of the system. The bus which covers maximum demand for various flow patterns has been selected for PMU placement. Sequential placement of PMU is considered with gradual increment in number of PMUs till whole demand of the system is covered. The proposed PMU placement technique has been tested on IEEE-14 and New England-39 bus system.
顺序PMU放置,以监测综合电力系统的功率流
本文提出了一种按顺序放置相量测量单元(PMU)来监测输电线路潮流的新方法。该方法是基于系统的实际潮流和负荷需求。利用潮流技术确定了给定负荷下的实际潮流模式。由于电力系统不断受到负荷变化的影响,在各母线上增加负荷可以得到不同的负荷流模式。在固定的流量覆盖准则下,从不同的流型生成了不同的流量覆盖矩阵。利用这些流量覆盖矩阵来确定满足系统最大需求的总线。公交车覆盖了各种流量模式的最大需求,被选择放置PMU。考虑PMU的顺序配置,逐步增加PMU的数量,直到满足系统的全部需求。所提出的PMU放置技术已在IEEE-14和新英格兰-39总线系统上进行了测试。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信