{"title":"Leaky Heating Coils of an Austenitic Chromium-Nickel-Molybdenum Steel","authors":"F. Naumann, F. Spies","doi":"10.31399/asm.fach.modes.c9001177","DOIUrl":null,"url":null,"abstract":"\n A solution containing 50 to 70% calcium chloride (pH 7.5 to 8.5) was concentrated by evaporation in a brick-lined vessel by passing steam at a pressure of 15 atmospheres through a system of heating coils made of austenitic stainless steel X 10 Cr-Ni-Mo-Ti 18 12 (Material No. 1.4573). After five months one of the coils, which consisted of tubes having a wall thickness of 3.4 mm, developed a leak. Tightly closed cracks were seen on the outer surface of the tube. Further tests with color penetration process revealed multiple branched cracks. Longitudinal section showed that the cracks had started from the outside surface of the tube. Electrolytic etching further showed that they had propagated mainly across the grains. It was concluded that this was a typical case of transcrystalline stress corrosion.","PeriodicalId":231268,"journal":{"name":"ASM Failure Analysis Case Histories: Failure Modes and Mechanisms","volume":"43 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ASM Failure Analysis Case Histories: Failure Modes and Mechanisms","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31399/asm.fach.modes.c9001177","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
A solution containing 50 to 70% calcium chloride (pH 7.5 to 8.5) was concentrated by evaporation in a brick-lined vessel by passing steam at a pressure of 15 atmospheres through a system of heating coils made of austenitic stainless steel X 10 Cr-Ni-Mo-Ti 18 12 (Material No. 1.4573). After five months one of the coils, which consisted of tubes having a wall thickness of 3.4 mm, developed a leak. Tightly closed cracks were seen on the outer surface of the tube. Further tests with color penetration process revealed multiple branched cracks. Longitudinal section showed that the cracks had started from the outside surface of the tube. Electrolytic etching further showed that they had propagated mainly across the grains. It was concluded that this was a typical case of transcrystalline stress corrosion.
将含有50%至70%氯化钙(pH值为7.5至8.5)的溶液在砖内衬容器中蒸发浓缩,蒸汽在15个大气压下通过由奥氏体不锈钢x10cr - ni - mo - ti 1812(材料号1.4573)制成的加热盘管系统。五个月后,其中一个由壁厚为3.4毫米的管子组成的线圈出现了泄漏。管的外表面有紧密闭合的裂缝。进一步的彩色渗透试验发现了多个分支裂纹。纵断面显示,裂纹是从管的外表面开始的。电解蚀刻进一步表明,它们主要在晶粒间传播。结果表明,这是典型的跨晶应力腐蚀。