Investigations on Feasibility of Fault Detection in Underground Power Cables Using SFRA

Aritra Das, Charu Sehgal, C. Reddy
{"title":"Investigations on Feasibility of Fault Detection in Underground Power Cables Using SFRA","authors":"Aritra Das, Charu Sehgal, C. Reddy","doi":"10.1109/CATCON47128.2019.CN0015","DOIUrl":null,"url":null,"abstract":"One of the most strenuous task is to locate the position of fault in power cables. There are many techniques which are available to locate faults, but each one have its own advantages and disadvantages. Contrary to the conventional reflectometry based methods, this paper explores a technique based on Sweep frequency response analysis (SFRA) in which reflection of the wave are not required. Sweep frequency response analysis (SFRA) are mostly used in transformer for checking the healthiness of its winding and to locate different faults and defects in it. In this paper using the same concept of SFRA in transformer, detection and location of fault in a cable has been investigated using PSpice simulation.","PeriodicalId":183797,"journal":{"name":"2019 IEEE 4th International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)","volume":"11 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE 4th International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CATCON47128.2019.CN0015","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

One of the most strenuous task is to locate the position of fault in power cables. There are many techniques which are available to locate faults, but each one have its own advantages and disadvantages. Contrary to the conventional reflectometry based methods, this paper explores a technique based on Sweep frequency response analysis (SFRA) in which reflection of the wave are not required. Sweep frequency response analysis (SFRA) are mostly used in transformer for checking the healthiness of its winding and to locate different faults and defects in it. In this paper using the same concept of SFRA in transformer, detection and location of fault in a cable has been investigated using PSpice simulation.
基于SFRA的地下电力电缆故障检测可行性研究
在电力电缆中定位故障位置是最困难的工作之一。有许多技术可用于定位故障,但每一个都有自己的优点和缺点。与传统的基于反射法的方法相反,本文探索了一种基于扫描频响分析(SFRA)的技术,该技术不需要波的反射。扫描频响分析(SFRA)主要用于检查变压器绕组的健康状况,定位变压器的各种故障和缺陷。本文采用变压器SFRA的相同概念,利用PSpice仿真对电缆故障的检测和定位进行了研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信