{"title":"[Current problems of the effects of contact ultrasound in medicine and other branches of the national economy].","authors":"L V Prokopenko","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The physiological and hygienic estimation of the working conditions of the new occupational groups of medical workers who service ultrasound (diagnostic, surgical, sterilization, and physiotherapeutic) equipment has demonstrated the intensity of contact ultrasound in the area of contact with hands to undergo changes within wide limits; exposure also changes, correspondingly by a factor of 10 or 10(2), amounting on the average to 1.2-1104 joules for different occupational groups. As a result of the long-term exposure to ultrasonic sources, the workers may develop neurovascular dose-dependent disorders in the form of angiodystonic syndrome of vegetative polyneuritis of the hands. The rate of the augmentation of constant shifts of the thresholds of vibration sensitivity may constitute 1.3 and 0.9 dB per year for those exposed to low and high-frequency sources, respectively. The principle of the frequency dependence of the effects of contact ultrasound is thus based; the maximum permissible level of factor is corrected with regard to the spectral parameters. The joint action of air and contact ultrasound has been examined and the additive effect has been revealed. This made it possible to establish a decreasing correction (5 dB) for the maximum permissible level of contact ultrasound characterized by a more remarkable biological action. The hygienic classification of contact ultrasound has been elaborated, the use of a complex of preventive measures has been based.</p>","PeriodicalId":76796,"journal":{"name":"Vestnik Akademii meditsinskikh nauk SSSR","volume":" 1","pages":"41-5"},"PeriodicalIF":0.0000,"publicationDate":"1992-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Vestnik Akademii meditsinskikh nauk SSSR","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The physiological and hygienic estimation of the working conditions of the new occupational groups of medical workers who service ultrasound (diagnostic, surgical, sterilization, and physiotherapeutic) equipment has demonstrated the intensity of contact ultrasound in the area of contact with hands to undergo changes within wide limits; exposure also changes, correspondingly by a factor of 10 or 10(2), amounting on the average to 1.2-1104 joules for different occupational groups. As a result of the long-term exposure to ultrasonic sources, the workers may develop neurovascular dose-dependent disorders in the form of angiodystonic syndrome of vegetative polyneuritis of the hands. The rate of the augmentation of constant shifts of the thresholds of vibration sensitivity may constitute 1.3 and 0.9 dB per year for those exposed to low and high-frequency sources, respectively. The principle of the frequency dependence of the effects of contact ultrasound is thus based; the maximum permissible level of factor is corrected with regard to the spectral parameters. The joint action of air and contact ultrasound has been examined and the additive effect has been revealed. This made it possible to establish a decreasing correction (5 dB) for the maximum permissible level of contact ultrasound characterized by a more remarkable biological action. The hygienic classification of contact ultrasound has been elaborated, the use of a complex of preventive measures has been based.
对使用超声(诊断、手术、绝育和物理治疗)设备的新职业医疗工作者群体的工作条件进行的生理和卫生评估表明,接触超声的强度在与手接触的区域可以在很大范围内发生变化;暴露量也相应变化,以10或10(2)的倍数变化,不同职业群体的平均暴露量为1.2-1104焦耳。由于长期暴露于超声波源,工人可能会出现神经血管剂量依赖性疾病,表现为手部植物性多神经炎血管张力障碍综合征。对于低频源和高频源,振动灵敏度阈值的恒定位移增加率分别为1.3和0.9 dB /年。接触超声效应的频率依赖性原理是这样建立的;根据光谱参数对因子的最大允许水平进行校正。研究了空气与接触式超声的联合作用,揭示了二者的加性效应。这使得有可能建立一个递减校正(5db)的最大允许水平的接触超声特征更显著的生物作用。对接触式超声的卫生分类进行了阐述,提出了一套综合的预防措施。