Brief review of partial volume corrections in PET/CT for lung cancer assessment

Sourour Gargouri, A. Mouelhi, M. Sayadi, S. Labidi, Majdi Mahersi, S. Zayed
{"title":"Brief review of partial volume corrections in PET/CT for lung cancer assessment","authors":"Sourour Gargouri, A. Mouelhi, M. Sayadi, S. Labidi, Majdi Mahersi, S. Zayed","doi":"10.1109/ATSIP.2018.8364481","DOIUrl":null,"url":null,"abstract":"The Partial Volume Effect (PVE) is considered as one of the main causes of PET/CT image blurring. The low resulted spatial resolution affects the accuracy of the diagnosis, and makes the staging and the prognosis of lung cancer more difficult. Restoring images through the use of Partial Volume Corrections (PVC) techniques allows a better quantitative estimation of the tumor uptake and a more efficient image analysis. The purpose of this study, is to cover the different approaches proposed in the literature used to correct the PVE in PET/CT in relation with lung cancer.","PeriodicalId":332253,"journal":{"name":"2018 4th International Conference on Advanced Technologies for Signal and Image Processing (ATSIP)","volume":"03 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-03-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 4th International Conference on Advanced Technologies for Signal and Image Processing (ATSIP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ATSIP.2018.8364481","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The Partial Volume Effect (PVE) is considered as one of the main causes of PET/CT image blurring. The low resulted spatial resolution affects the accuracy of the diagnosis, and makes the staging and the prognosis of lung cancer more difficult. Restoring images through the use of Partial Volume Corrections (PVC) techniques allows a better quantitative estimation of the tumor uptake and a more efficient image analysis. The purpose of this study, is to cover the different approaches proposed in the literature used to correct the PVE in PET/CT in relation with lung cancer.
简要回顾PET/CT部分体积校正在肺癌评估中的应用
部分体积效应(PVE)是引起PET/CT图像模糊的主要原因之一。结果空间分辨率低影响了诊断的准确性,使肺癌的分期和预后更加困难。通过使用部分体积校正(PVC)技术恢复图像可以更好地定量估计肿瘤摄取和更有效的图像分析。本研究的目的是涵盖文献中提出的用于纠正与肺癌相关的PET/CT PVE的不同方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信