{"title":"Design and Control of a Grid-connected Seven Level Inverter for Photovoltaic Applications","authors":"F. Mulolani, Francis Kafata, Esau Zulu","doi":"10.33260/ZICTJOURNAL.V3I1.72","DOIUrl":null,"url":null,"abstract":"This paper presents the design and closed-loop current control of a grid connected seven-level, 3-phase diode-clamped multilevel inverter for Photovoltaic (PV) applications. The proposed closed loop current control technique is based on the voltage-oriented proportional integral (PI) controller theory. The modulation technique used is level-shifted-carrier sinusoidal pulse width modulation (SPWM). The gain values of PI controller were selected to achieve good current quality and dynamic response. Grid synchronization was achieved by using a synchronous-reference frame phase-locked loop (SRF-PLL). Matlab/Simulink was used for the control system design and simulation. The simulation results show that a 1.34% total harmonic distortion (THD) of the output current was achieved which is within the allowable current distortion limits by international standards. The stability of the system was analyzed using pole-zero mapping and root locus.","PeriodicalId":206279,"journal":{"name":"Zambia ICT Journal","volume":"29 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-03-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zambia ICT Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33260/ZICTJOURNAL.V3I1.72","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
This paper presents the design and closed-loop current control of a grid connected seven-level, 3-phase diode-clamped multilevel inverter for Photovoltaic (PV) applications. The proposed closed loop current control technique is based on the voltage-oriented proportional integral (PI) controller theory. The modulation technique used is level-shifted-carrier sinusoidal pulse width modulation (SPWM). The gain values of PI controller were selected to achieve good current quality and dynamic response. Grid synchronization was achieved by using a synchronous-reference frame phase-locked loop (SRF-PLL). Matlab/Simulink was used for the control system design and simulation. The simulation results show that a 1.34% total harmonic distortion (THD) of the output current was achieved which is within the allowable current distortion limits by international standards. The stability of the system was analyzed using pole-zero mapping and root locus.