Experimental Study for the Effect of the Modified Twisted Tape Insert on Heat Transfer Through Circular Tube

Y. B. Patil, J.P. Shete
{"title":"Experimental Study for the Effect of the Modified Twisted Tape Insert on Heat Transfer Through Circular Tube","authors":"Y. B. Patil, J.P. Shete","doi":"10.2139/ssrn.3101281","DOIUrl":null,"url":null,"abstract":"This work presents an experimental study on the mean Nusselt number, friction factor and enhancement efficiency characteristics in a circular tube. This was investigated for four twist ratios (Y= 2.3, 2.9, 3.5, and 4.1) The obtained results show that the mean Nusselt number and the mean friction factor in the tube with Plain, Perforated, perforated with notch type twisted tapes inserts increase with decreasing twist ratios (Y). Subsequently, an empirical correlation also was formulated to match with experimental results with ±4.22% variation for the Nusselt number and 5.59% for the friction factor. Also, the experimental results show higher values of heat transfer for perforated with notch type insert for higher values of Re. And shows lower values of friction factor for higher values of Re. Maximum F is observed for the insert with perforation with notch having Y=2.3. The average F increases 5 to 7 times than that of the plain tube and the heat transfer enhancement ranges from 2.9 to 3.3 times that of the plain tube over the range of Re 10000 to 16000 with air as working fluid.","PeriodicalId":277472,"journal":{"name":"Advances in Thermal Systems","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-12-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in Thermal Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2139/ssrn.3101281","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This work presents an experimental study on the mean Nusselt number, friction factor and enhancement efficiency characteristics in a circular tube. This was investigated for four twist ratios (Y= 2.3, 2.9, 3.5, and 4.1) The obtained results show that the mean Nusselt number and the mean friction factor in the tube with Plain, Perforated, perforated with notch type twisted tapes inserts increase with decreasing twist ratios (Y). Subsequently, an empirical correlation also was formulated to match with experimental results with ±4.22% variation for the Nusselt number and 5.59% for the friction factor. Also, the experimental results show higher values of heat transfer for perforated with notch type insert for higher values of Re. And shows lower values of friction factor for higher values of Re. Maximum F is observed for the insert with perforation with notch having Y=2.3. The average F increases 5 to 7 times than that of the plain tube and the heat transfer enhancement ranges from 2.9 to 3.3 times that of the plain tube over the range of Re 10000 to 16000 with air as working fluid.
改进型扭带插片对圆管传热影响的实验研究
本文对圆管内平均努塞尔数、摩擦因数和增强效率特性进行了实验研究。结果表明,在4种扭转比(Y= 2.3、2.9、3.5和4.1)条件下,普通、穿孔、缺口型扭曲带插入管的平均努塞尔数和平均摩擦系数随扭转比(Y)的减小而增大,与实验结果相匹配,努塞尔数变化幅度为±4.22%,摩擦系数变化幅度为5.59%。同时,实验结果表明,随着Re值的增大,缺口型插片的换热系数增大;随着Re值的增大,摩擦系数减小。对于Y=2.3的缺口型插片,F值最大。在Re 10000 ~ 16000范围内,空气为工质时,平均F值是普通管的5 ~ 7倍,传热强化是普通管的2.9 ~ 3.3倍。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信