Line outage detection using optimal number of Phasor Measurement Unit

H. Kumar, R. Dahiya
{"title":"Line outage detection using optimal number of Phasor Measurement Unit","authors":"H. Kumar, R. Dahiya","doi":"10.1109/i-PACT44901.2019.8960027","DOIUrl":null,"url":null,"abstract":"The power distribution network needs to be monitored in an effective manner against the line outages. Phasor Measurement Unit (PMU) is a device which is used to estimate the magnitude and phase angle of an electrical phasor quantity. PMUs are distributed globally to provide time synchronized information to operators through phasor data concentrator. In this paper, a new algorithm to identify single line outage using the PMU has been proposed. The voltage phasor angles are taken only at buses where the PMUs are located. Further the optimal location of PMUs is identified by an algorithm based on maximum connectivity of buses. Proposed algorithm is developed in MATLAB environment and tested on IEEE 9 bus system which is simulated in PSAT software.","PeriodicalId":214890,"journal":{"name":"2019 Innovations in Power and Advanced Computing Technologies (i-PACT)","volume":"54 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 Innovations in Power and Advanced Computing Technologies (i-PACT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/i-PACT44901.2019.8960027","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

The power distribution network needs to be monitored in an effective manner against the line outages. Phasor Measurement Unit (PMU) is a device which is used to estimate the magnitude and phase angle of an electrical phasor quantity. PMUs are distributed globally to provide time synchronized information to operators through phasor data concentrator. In this paper, a new algorithm to identify single line outage using the PMU has been proposed. The voltage phasor angles are taken only at buses where the PMUs are located. Further the optimal location of PMUs is identified by an algorithm based on maximum connectivity of buses. Proposed algorithm is developed in MATLAB environment and tested on IEEE 9 bus system which is simulated in PSAT software.
采用最优相量测量单元数进行线路中断检测
需要对配电网进行有效的监控,防止线路出现故障。相量测量单元(PMU)是一种用于估计电相量的大小和相角的装置。pmu分布全局,通过相量数据集中器向操作员提供时间同步信息。本文提出了一种利用PMU识别单线中断的新算法。电压相量角仅在pmu所在的总线上取。采用基于总线最大连通性的算法确定pmu的最优位置。该算法在MATLAB环境下进行了开发,并在IEEE 9总线系统上进行了测试,并在PSAT软件中进行了仿真。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信