{"title":"Stability improvement of a HVDC transmission link between weak AC systems by multi-terminal scheme","authors":"A. Nnachi, J. Munda, D. Nicolae, A. M. Mabwe","doi":"10.1109/AFRCON.2013.6757810","DOIUrl":null,"url":null,"abstract":"But, the problem of voltage stability for weak AC systems interconnected by a DC link is critical especially during islanding conditions. The approach to improve more on the stability of such system would be to device a means of injecting locally controlled dc power on the dc-link transmission corridor forming a radial multi-terminal HVDC. However, continuous injection of DC power on the dc line of the VSC HVDC link though will increase the power transfer capability of the system but should have a limit otherwise it will lead to instability of the system. In this paper, a detailed VSC HVDC model and a simple analytical technique using the principle of uniform loading to determine penetration limit is presented. The techniques is applied to our case study and validated with a simulation result. Critical contingencies such as sudden island conditions, three-phase to ground fault are simulated with and without DC power penetration. Results show the stability support on the AC side networks by DC power injection on the dc-link.","PeriodicalId":159306,"journal":{"name":"2013 Africon","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 Africon","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/AFRCON.2013.6757810","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
But, the problem of voltage stability for weak AC systems interconnected by a DC link is critical especially during islanding conditions. The approach to improve more on the stability of such system would be to device a means of injecting locally controlled dc power on the dc-link transmission corridor forming a radial multi-terminal HVDC. However, continuous injection of DC power on the dc line of the VSC HVDC link though will increase the power transfer capability of the system but should have a limit otherwise it will lead to instability of the system. In this paper, a detailed VSC HVDC model and a simple analytical technique using the principle of uniform loading to determine penetration limit is presented. The techniques is applied to our case study and validated with a simulation result. Critical contingencies such as sudden island conditions, three-phase to ground fault are simulated with and without DC power penetration. Results show the stability support on the AC side networks by DC power injection on the dc-link.