Hua-Xuan Li, H. Fu, Shi-Yu Huang, Jin-Cheng Jiang, D. Kwai, Yung-Fa Chou
{"title":"Testing power-delivery TSVs","authors":"Hua-Xuan Li, H. Fu, Shi-Yu Huang, Jin-Cheng Jiang, D. Kwai, Yung-Fa Chou","doi":"10.1109/ACQED.2015.7274021","DOIUrl":null,"url":null,"abstract":"Many TSVs in a 3D IC are not used for signal transmission but for power delivery. Techniques needed to detect them have not been studied in-depth in the literature. In this paper, we present a test method for power-delivery TSVs, by embedding ring-oscillator (RO) based monitors (in a scalable architecture) to detect if there is any excessive voltage-drop at the end of any TSV during a manufacturing test session. One key feature as opposed to previous RO-based methods is that our approach is able to detect the worst-case dynamic voltage-drop (occurring in a very short period of time such as 1ns), rather than just the average voltage-drop over a long period of time. This is essential in order to detect small defects inside the power delivery network. These defects, if not detected, could set off a transient timing failure when the IC is operated in a system.","PeriodicalId":376857,"journal":{"name":"2015 6th Asia Symposium on Quality Electronic Design (ASQED)","volume":"3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 6th Asia Symposium on Quality Electronic Design (ASQED)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ACQED.2015.7274021","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4
Abstract
Many TSVs in a 3D IC are not used for signal transmission but for power delivery. Techniques needed to detect them have not been studied in-depth in the literature. In this paper, we present a test method for power-delivery TSVs, by embedding ring-oscillator (RO) based monitors (in a scalable architecture) to detect if there is any excessive voltage-drop at the end of any TSV during a manufacturing test session. One key feature as opposed to previous RO-based methods is that our approach is able to detect the worst-case dynamic voltage-drop (occurring in a very short period of time such as 1ns), rather than just the average voltage-drop over a long period of time. This is essential in order to detect small defects inside the power delivery network. These defects, if not detected, could set off a transient timing failure when the IC is operated in a system.