Imaging of a focal liver lesion using ordered subset expectation maximization technique

T.J. Jeon, H. Kim, J. Bong, J. Lee, M. Kim, H.S. Yoo
{"title":"Imaging of a focal liver lesion using ordered subset expectation maximization technique","authors":"T.J. Jeon, H. Kim, J. Bong, J. Lee, M. Kim, H.S. Yoo","doi":"10.1109/NSSMIC.2000.949381","DOIUrl":null,"url":null,"abstract":"RBC blood pool SPECT has been used to diagnose focal liver lesions such as hemangioma because of its high specificity. However, its low spatial resolution is a major limitation. Recently, ordered subset expectation maximization (OSEM) has been introduced to obtain tomographic images for clinical application. The authors compared this new modified iterative reconstruction method with conventional filtered back projection (FBP) in the imaging of liver hemangioma. Sixty four projection data were acquired using a dual head gamma camera in 25 patients with cavernous hemangioma of the liver, and this raw data was transferred to a LINUX based personal computer. After the replacement of the header file as an interfile, OSEM was performed under various conditions of subsets (1,2,4,8,16, and 32) and iteration numbers (1,2,4,8, and 16) to obtain the best setting for liver imaging, which in the authors' investigation was considered to be 4 iterations and 16 subsets. After this process, all the images processed by FBP and OSEM, in the same cases, were evaluated by 3 experts. According to a blind review of 28 lesions, OSEM images revealed at least same or better qualities than FBP in nearly all cases. Although there was no significant difference in the detection of large lesions (67.9%), 5 small lesions (17.9%) were detected by OSEM only. However, both techniques failed to depict 4 cases of small lesions (14.3%). In conclusion, OSEM revealed better contrast and definition in the depiction of liver hemangioma, and a higher sensitivity in the detection of small lesions. Furthermore, this reconstruction method didn't require a higher computer system or protracted reconstruction time, therefore, OSEM offers a good method that can be applied to RBC blood pool SPECT for the diagnosis of liver hemangioma.","PeriodicalId":445100,"journal":{"name":"2000 IEEE Nuclear Science Symposium. Conference Record (Cat. No.00CH37149)","volume":"7 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2000-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2000 IEEE Nuclear Science Symposium. Conference Record (Cat. No.00CH37149)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2000.949381","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

RBC blood pool SPECT has been used to diagnose focal liver lesions such as hemangioma because of its high specificity. However, its low spatial resolution is a major limitation. Recently, ordered subset expectation maximization (OSEM) has been introduced to obtain tomographic images for clinical application. The authors compared this new modified iterative reconstruction method with conventional filtered back projection (FBP) in the imaging of liver hemangioma. Sixty four projection data were acquired using a dual head gamma camera in 25 patients with cavernous hemangioma of the liver, and this raw data was transferred to a LINUX based personal computer. After the replacement of the header file as an interfile, OSEM was performed under various conditions of subsets (1,2,4,8,16, and 32) and iteration numbers (1,2,4,8, and 16) to obtain the best setting for liver imaging, which in the authors' investigation was considered to be 4 iterations and 16 subsets. After this process, all the images processed by FBP and OSEM, in the same cases, were evaluated by 3 experts. According to a blind review of 28 lesions, OSEM images revealed at least same or better qualities than FBP in nearly all cases. Although there was no significant difference in the detection of large lesions (67.9%), 5 small lesions (17.9%) were detected by OSEM only. However, both techniques failed to depict 4 cases of small lesions (14.3%). In conclusion, OSEM revealed better contrast and definition in the depiction of liver hemangioma, and a higher sensitivity in the detection of small lesions. Furthermore, this reconstruction method didn't require a higher computer system or protracted reconstruction time, therefore, OSEM offers a good method that can be applied to RBC blood pool SPECT for the diagnosis of liver hemangioma.
肝局灶性病变的有序亚群期望最大化成像技术
红细胞血池SPECT因其高特异性已被用于肝血管瘤等局灶性病变的诊断。然而,它的主要限制是低空间分辨率。近年来,有序子集期望最大化(OSEM)被引入到断层成像的临床应用中。作者将这种改进的迭代重建方法与传统的滤波反投影(FBP)在肝血管瘤成像中的应用进行了比较。本文对25例肝海绵状血管瘤患者采用双头伽玛相机采集了64个投影数据,并将这些原始数据传输到基于LINUX的个人计算机上。将头文件替换为interfile后,在不同的子集(1、2、4、8、16、32)和迭代数(1、2、4、8、16)条件下进行OSEM,以获得肝脏成像的最佳设置,在作者的研究中认为为4次迭代和16个子集。在此过程之后,FBP和OSEM处理的所有图像,在相同的情况下,由3名专家进行评估。根据对28个病变的盲检,OSEM图像显示几乎所有病例的质量至少与FBP相同或更好。虽然OSEM对大病变的检出率(67.9%)无显著差异,但对5个小病变的检出率(17.9%)仅为OSEM。然而,两种技术均未能描绘出4例小病变(14.3%)。综上所述,OSEM在肝脏血管瘤的描述中具有更好的对比度和清晰度,在小病变的检测中具有更高的灵敏度。此外,该重建方法对计算机系统要求不高,重建时间不长,因此OSEM是一种很好的方法,可以应用于红细胞血池SPECT诊断肝血管瘤。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信