Novel Velocity Update Applied for IMU-based Wearable Device to Estimate the Vertical Distance

T. Do, U-Xuan Tan
{"title":"Novel Velocity Update Applied for IMU-based Wearable Device to Estimate the Vertical Distance","authors":"T. Do, U-Xuan Tan","doi":"10.1109/ICECIE47765.2019.8974671","DOIUrl":null,"url":null,"abstract":"The demand for indoor localization that does not rely on the presence of any external infrastructure had been increasing. In general, an indoor localization system was required to be precise, highly accurate and reliable. In this paper, we presented and analyzed an indoor localization wearable device that was capable of positioning people while riding in an elevator. The inertial measurement unit (IMU) was utilized with an embedded system on the device. Current approaches involving IMU mounted on a pedestrian's body generally estimated the displacement on the ground only (in two dimensions). Thinking of a wearable device to estimate the vertical distance for elevator riding and with the fact that there are different levels of height for different buildings, a new algorithm was proposed to estimate distance in vertical direction when people riding in an elevator. The proposed algorithm was based on the double integrating process from global acceleration with gravity removal in which the velocity and distance are updated in periods that the vertical acceleration oscillates around Zero level. Experiments with a wearable device which was designed based on the IMU model MPU9150, Arduino board and wireless Xbee took place for riding in an elevator. Experimental results contained device's attitude, vertical distance and time stamp. They were recorded online wirelessly via Xbee devices into an *txt file. Experiments in this work include riding up and down in an elevator. They were repeated to collect data for evaluation by root mean square error (RMSE) computation based on the ground-truth. The experimental results demonstrated RMSE of 0.77%, 0.88%, 1.66% riding in an elevator through one floor only, riding in an elevator through multiple floors while stopping at each floor, riding in an elevator through 40 floors, respectively.","PeriodicalId":154051,"journal":{"name":"2019 1st International Conference on Electrical, Control and Instrumentation Engineering (ICECIE)","volume":"96 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 1st International Conference on Electrical, Control and Instrumentation Engineering (ICECIE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICECIE47765.2019.8974671","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

The demand for indoor localization that does not rely on the presence of any external infrastructure had been increasing. In general, an indoor localization system was required to be precise, highly accurate and reliable. In this paper, we presented and analyzed an indoor localization wearable device that was capable of positioning people while riding in an elevator. The inertial measurement unit (IMU) was utilized with an embedded system on the device. Current approaches involving IMU mounted on a pedestrian's body generally estimated the displacement on the ground only (in two dimensions). Thinking of a wearable device to estimate the vertical distance for elevator riding and with the fact that there are different levels of height for different buildings, a new algorithm was proposed to estimate distance in vertical direction when people riding in an elevator. The proposed algorithm was based on the double integrating process from global acceleration with gravity removal in which the velocity and distance are updated in periods that the vertical acceleration oscillates around Zero level. Experiments with a wearable device which was designed based on the IMU model MPU9150, Arduino board and wireless Xbee took place for riding in an elevator. Experimental results contained device's attitude, vertical distance and time stamp. They were recorded online wirelessly via Xbee devices into an *txt file. Experiments in this work include riding up and down in an elevator. They were repeated to collect data for evaluation by root mean square error (RMSE) computation based on the ground-truth. The experimental results demonstrated RMSE of 0.77%, 0.88%, 1.66% riding in an elevator through one floor only, riding in an elevator through multiple floors while stopping at each floor, riding in an elevator through 40 floors, respectively.
基于imu可穿戴设备的新型速度更新估计垂直距离
不依赖于任何外部基础设施的室内定位需求一直在增加。一般来说,室内定位系统要求精度高、精度高、可靠性好。本文提出并分析了一种室内定位可穿戴设备,该设备能够在乘坐电梯时对人进行定位。惯性测量单元(IMU)采用嵌入式系统。目前涉及将IMU安装在行人身上的方法通常只估计地面上的位移(二维)。考虑到可穿戴设备对乘电梯垂直距离的估计,结合不同建筑高度的不同,提出了一种估算人乘电梯垂直方向距离的新算法。该算法基于消除重力的全局加速度的双重积分过程,在垂直加速度在零水平附近振荡的周期内更新速度和距离。利用基于IMU型号MPU9150、Arduino板和无线Xbee设计的可穿戴设备进行电梯乘坐实验。实验结果包含了装置的姿态、垂直距离和时间戳。它们通过Xbee设备无线在线录制到*txt文件中。这项工作的实验包括乘坐电梯上上下下。他们被重复收集数据,以评估基于基本事实的均方根误差(RMSE)计算。实验结果表明,仅乘一层电梯、乘多层电梯并在每层停车、乘40层电梯的RMSE分别为0.77%、0.88%、1.66%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信