Fault detection and isolation for PEM fuel cell stacks using fuzzy clusters

M. Buchholz, G. Pêcheur, Jens Niemeyer, V. Krebs
{"title":"Fault detection and isolation for PEM fuel cell stacks using fuzzy clusters","authors":"M. Buchholz, G. Pêcheur, Jens Niemeyer, V. Krebs","doi":"10.23919/ECC.2007.7068720","DOIUrl":null,"url":null,"abstract":"Using polymer electrolyte membrane fuel cell (PEMFC) stacks as power supply in technical systems, a long life time and safe operation of the stack are important issues. Therefore, methods are needed to detect deviations from the chosen operating point before any damage to the stack or the environment occurs. In this paper, a fault detection and isolation (FDI) method for PEMFC stacks is described. Based on the measurement of current and voltage of the stack, deviations of other parameters like gas pressure, stoichiometry, or humidification of the supplied air can be detected and isolated.","PeriodicalId":407048,"journal":{"name":"2007 European Control Conference (ECC)","volume":"20 3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-07-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 European Control Conference (ECC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23919/ECC.2007.7068720","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Using polymer electrolyte membrane fuel cell (PEMFC) stacks as power supply in technical systems, a long life time and safe operation of the stack are important issues. Therefore, methods are needed to detect deviations from the chosen operating point before any damage to the stack or the environment occurs. In this paper, a fault detection and isolation (FDI) method for PEMFC stacks is described. Based on the measurement of current and voltage of the stack, deviations of other parameters like gas pressure, stoichiometry, or humidification of the supplied air can be detected and isolated.
基于模糊聚类的PEM燃料电池堆故障检测与隔离
聚合物电解质膜燃料电池(PEMFC)电池组作为技术系统的电源,其长寿命和安全运行是一个重要的问题。因此,需要在对堆栈或环境造成任何损害之前检测出偏离所选工作点的方法。本文介绍了一种用于PEMFC堆叠的故障检测与隔离方法。基于对堆叠电流和电压的测量,可以检测和隔离其他参数的偏差,如气体压力、化学计量或供气的加湿。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信