Planning Target Volume Margin Determination for Volumetric Modulated Arc Therapy Planning in Cervix Cancers Using an Empty Bladder Protocol

Anand Bunnachak, E. Tharavichitkul, S. Wanwilairat, W. Nobnop
{"title":"Planning Target Volume Margin Determination for Volumetric Modulated Arc Therapy Planning in Cervix Cancers Using an Empty Bladder Protocol","authors":"Anand Bunnachak, E. Tharavichitkul, S. Wanwilairat, W. Nobnop","doi":"10.12982/bscm.2023.08","DOIUrl":null,"url":null,"abstract":"OBJECTIVE To evaluate the planning target volume (PTV) margin and bladder volume variation of volumetric modulated arc therapy (VMAT) in cervical cancer using an empty bladder protocol. METHODS Ten patients with cervical cancer who had indications to receive whole pelvic radiotherapy and who had been identified to receive whole pelvic irradiation with a dose of 46-55.2 Gy in 23 fractions planned by VMAT were included. International Commission on Radiation Units and Measurements (ICRU) Report 83 was used to report plan parameters. The empty bladder protocol is designed for use with all patients before simulation and irradiation. From June 2020 to February 2021, 215 fractions from the 10 patients were evaluated. The ‘all fraction’ set-up errors were recorded using cone-beam computed tomography (CBCT) and were interpreted as error margins using the Van Herk Formula. RESULTS The calculated PTV margins were 0.75, 0.84, and 0.98 cm on the X, Y, and Z-axes, respectively. The median volume of the bladder before irradiation was 40.6 cc, with an interquartile range of 31.9 to 59.2 cc. The average change in bladder volume from the planning volume was 23.56%. CONCLUSIONS Using the empty bladder protocol, the clinical target volume (CTV) to PTV margin was 1 cm following the Van Herk formula. No patients experienced side effects of grade 3 or greater. The empty bladder protocol is a method which can reduce target placement error and reduce patient discomfort without causing serious side effects. KEYWORDS PTV margin, VMAT, IGRT, Cervix cancer, Empty bladder","PeriodicalId":405540,"journal":{"name":"Biomedical Sciences and Clinical Medicine","volume":"36 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-06-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical Sciences and Clinical Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.12982/bscm.2023.08","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

OBJECTIVE To evaluate the planning target volume (PTV) margin and bladder volume variation of volumetric modulated arc therapy (VMAT) in cervical cancer using an empty bladder protocol. METHODS Ten patients with cervical cancer who had indications to receive whole pelvic radiotherapy and who had been identified to receive whole pelvic irradiation with a dose of 46-55.2 Gy in 23 fractions planned by VMAT were included. International Commission on Radiation Units and Measurements (ICRU) Report 83 was used to report plan parameters. The empty bladder protocol is designed for use with all patients before simulation and irradiation. From June 2020 to February 2021, 215 fractions from the 10 patients were evaluated. The ‘all fraction’ set-up errors were recorded using cone-beam computed tomography (CBCT) and were interpreted as error margins using the Van Herk Formula. RESULTS The calculated PTV margins were 0.75, 0.84, and 0.98 cm on the X, Y, and Z-axes, respectively. The median volume of the bladder before irradiation was 40.6 cc, with an interquartile range of 31.9 to 59.2 cc. The average change in bladder volume from the planning volume was 23.56%. CONCLUSIONS Using the empty bladder protocol, the clinical target volume (CTV) to PTV margin was 1 cm following the Van Herk formula. No patients experienced side effects of grade 3 or greater. The empty bladder protocol is a method which can reduce target placement error and reduce patient discomfort without causing serious side effects. KEYWORDS PTV margin, VMAT, IGRT, Cervix cancer, Empty bladder
使用空膀胱方案的子宫颈癌体积调制弧线治疗计划的目标体积裕度确定
目的探讨空膀胱方案下体积调节弧线治疗宫颈癌的规划靶体积(PTV)边界和膀胱体积变化。方法选取10例符合全盆腔放疗指征、经VMAT计划的23次全盆腔放疗剂量为46 ~ 55.2 Gy的宫颈癌患者为研究对象。国际辐射单位和测量委员会(ICRU) 83号报告用于报告计划参数。空膀胱方案是为模拟和照射前的所有患者设计的。从2020年6月到2021年2月,对10例患者的215个部分进行了评估。使用锥束计算机断层扫描(CBCT)记录“所有分数”设置误差,并使用Van Herk公式解释为误差范围。结果在X、Y、z轴上PTV边界分别为0.75、0.84、0.98 cm。照射前膀胱容积中位数为40.6 cc,四分位数范围为31.9 ~ 59.2 cc,膀胱容积与计划容积相比平均变化23.56%。结论采用空膀胱方案,临床靶体积(CTV)到PTV切缘的距离为1 cm,符合Van Herk公式。没有患者出现3级或以上的副作用。空膀胱方案是一种既能减少靶位误差,又能减少患者不适,又不会产生严重副作用的方法。关键词PTV切缘,VMAT, IGRT,宫颈癌,空膀胱
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信