{"title":"Optimization of Overcurrent Relay Operation Using Artificial Intelligent on Radial Topology with Load Constraint","authors":"Nugraha Agung Wibowo, V. R. Mahindara, A. Priyadi, M. Pujiantara, M. Purnomo","doi":"10.1109/ISITIA.2018.8711089","DOIUrl":null,"url":null,"abstract":"Over current relay application on indutry requires some setting parameters such as pick up current (Ip), time dial setting (TDS), and operating time (top). There are some standards that stated the restrictions and formulations to determining those parameters. One of the problems is to determine the TDS on inverse relay (ANSI Code 51). Generally, the determination of TDS value is done by trial and error method, it is considered less effective so it is proposed a new method in determining TDS on real plant electrical system with radial topology system. Artificial Intelligent is used to determine TDS for protection relay and hopefully able to solve the problem in order to improve the effectiveness by considering the load constraint during optimization.","PeriodicalId":388463,"journal":{"name":"2018 International Seminar on Intelligent Technology and Its Applications (ISITIA)","volume":"48 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 International Seminar on Intelligent Technology and Its Applications (ISITIA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISITIA.2018.8711089","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Over current relay application on indutry requires some setting parameters such as pick up current (Ip), time dial setting (TDS), and operating time (top). There are some standards that stated the restrictions and formulations to determining those parameters. One of the problems is to determine the TDS on inverse relay (ANSI Code 51). Generally, the determination of TDS value is done by trial and error method, it is considered less effective so it is proposed a new method in determining TDS on real plant electrical system with radial topology system. Artificial Intelligent is used to determine TDS for protection relay and hopefully able to solve the problem in order to improve the effectiveness by considering the load constraint during optimization.
负载约束下径向拓扑过流继电器人工智能运行优化
工业上的过电流继电器应用需要一些设置参数,如拾取电流(Ip),时间拨号设置(TDS)和操作时间(top)。有一些标准规定了确定这些参数的限制和公式。其中一个问题是确定反继电器的TDS (ANSI Code 51)。由于TDS值的确定一般采用试错法,效率较低,因此提出了一种利用径向拓扑系统确定实际电厂电气系统TDS值的新方法。利用人工智能来确定保护继电器的TDS,在优化过程中考虑负载约束,希望能够解决这一问题,从而提高效率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信