A high efficiency conditioning method of vacuum interrupters by high frequency voltage impulses

He Yang, Yingsan Geng, Zhiyuan Liu, Xiaoshe Zai, Chaoran Wang
{"title":"A high efficiency conditioning method of vacuum interrupters by high frequency voltage impulses","authors":"He Yang, Yingsan Geng, Zhiyuan Liu, Xiaoshe Zai, Chaoran Wang","doi":"10.1109/DEIV.2012.6412451","DOIUrl":null,"url":null,"abstract":"It is well-known that the high-voltage withstand ability of vacuum interrupters (VIs) can be increased by conditioning processes. Several conventional conditioning methods, such as spark conditioning and current conditioning, are used by most vacuum interrupter manufacturers. However, the conditioning efficiency of these methods is low and the conditioning energy is high which would lead to an accompanying `de-conditioning' process. The objective of this paper is to propose a conditioning technique for vacuum interrupters by using a series of sub-microsecond voltage impulses that have a high conditioning efficiency and low conditioning energy. Two 7.2kV VIs are used to investigate the improvement of the basic impulse level (BIL) by this proposed technique, compared with the other two VIs which are conditioned by the conventional method. During the conditioning process, VI suffers several hundreds of batches of sub-microsecond high voltage impulses (1000Hz, 0.1s). The peak value of each impulse reaches 100kV. If a breakdown occurs, a high frequency conditioning current of several kA (peak value) would flow through the vacuum interrupter. The experimental results show that this conditioning technology has a higher efficiency compared with the conventional method by decreasing the conditioning process duration from several minutes to tens of seconds. The average value of the BIL voltages by using the new conditioning is 27% higher than that of the conventional conditioning. And the scattering of the breakdown voltage could be reduced by 31%. The conditioned area occupies to the whole contact surface after the high frequency voltage impulses conditioning, which is superior to that of the conventional conditioning.","PeriodicalId":130964,"journal":{"name":"2012 25th International Symposium on Discharges and Electrical Insulation in Vacuum (ISDEIV)","volume":"12 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"12","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 25th International Symposium on Discharges and Electrical Insulation in Vacuum (ISDEIV)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/DEIV.2012.6412451","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 12

Abstract

It is well-known that the high-voltage withstand ability of vacuum interrupters (VIs) can be increased by conditioning processes. Several conventional conditioning methods, such as spark conditioning and current conditioning, are used by most vacuum interrupter manufacturers. However, the conditioning efficiency of these methods is low and the conditioning energy is high which would lead to an accompanying `de-conditioning' process. The objective of this paper is to propose a conditioning technique for vacuum interrupters by using a series of sub-microsecond voltage impulses that have a high conditioning efficiency and low conditioning energy. Two 7.2kV VIs are used to investigate the improvement of the basic impulse level (BIL) by this proposed technique, compared with the other two VIs which are conditioned by the conventional method. During the conditioning process, VI suffers several hundreds of batches of sub-microsecond high voltage impulses (1000Hz, 0.1s). The peak value of each impulse reaches 100kV. If a breakdown occurs, a high frequency conditioning current of several kA (peak value) would flow through the vacuum interrupter. The experimental results show that this conditioning technology has a higher efficiency compared with the conventional method by decreasing the conditioning process duration from several minutes to tens of seconds. The average value of the BIL voltages by using the new conditioning is 27% higher than that of the conventional conditioning. And the scattering of the breakdown voltage could be reduced by 31%. The conditioned area occupies to the whole contact surface after the high frequency voltage impulses conditioning, which is superior to that of the conventional conditioning.
一种利用高频电压脉冲对真空灭流器进行高效调理的方法
众所周知,真空灭弧器的耐高压能力可以通过调节工艺来提高。几种常规的调节方法,如火花调节和电流调节,是大多数真空灭弧器制造商使用的。然而,这些方法的调理效率低,调理能量高,会导致伴随的“去调理”过程。本文的目的是提出一种利用一系列亚微秒电压脉冲对真空灭流器进行调节的技术,该技术具有高调节效率和低调节能量。用两个7.2kV的VIs来研究该技术对基本脉冲电平(BIL)的改善,并与其他两个由传统方法调节的VIs进行了比较。在调理过程中,VI遭受了数百批次亚微秒级高压脉冲(1000Hz, 0.1s)。每个脉冲的峰值达到100kV。当击穿发生时,一个几kA(峰值)的高频调节电流将流过真空断流器。实验结果表明,与传统的调质方法相比,该技术将调质时间从几分钟缩短到几十秒,具有更高的效率。采用新调节后的BIL电压平均值比常规调节高27%。击穿电压的散射可以降低31%。高频电压脉冲调理后的调理面积占整个接触面,优于常规调理。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信