{"title":"CHARACTERISTICS OF ETS EXPOSURE IN INTERNET CAFES, PUBS, AND POOL HALLS AROUND A UNIVERSITY CAMPUS","authors":"Kwonchul Ha","doi":"10.2495/EID180411","DOIUrl":null,"url":null,"abstract":"The aims of this study were to determine the indoor level of environmental tobacco smoke (ETS) and to assess the implementation rate of smoke-free law at hospitality venues around a university campus by measuring particulate matter smaller than 2.5 μm (PM2.5) as an indicator of ETS. We measured the indoor PM2.5 concentrations at 20 internet cafes, 20 pubs, and 20 pool halls using Sidepak AM510, a direct reading portable real time monitor, from October to December 2015. Smoking was observed in 65% of internet cafes, 10% of pubs, and 85% of pool halls. The average of PM2.5 concentration was 98.2 μg/m3, 29.0 μg/m3, and 134.2 μg/m3 at internet cafes, pubs, and pool halls, respectively. PM2.5 concentrations in internet cafes and pool halls were 2 to 2.7 times higher than the 24 hour exposure standard for outdoor PM2.5 (50 μg/m3) of the Ministry of the Environment. Although a smoking ban had been implemented at internet cafes and pubs, smoking is still taking place in those places. More stringent legal action are required for the success of legal action to protect patrons and workers from second-hand smoke exposure. The ban on smoking in pool halls should be introduced as soon as","PeriodicalId":217537,"journal":{"name":"Environmental Impact IV","volume":"152 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-06-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Environmental Impact IV","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2495/EID180411","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The aims of this study were to determine the indoor level of environmental tobacco smoke (ETS) and to assess the implementation rate of smoke-free law at hospitality venues around a university campus by measuring particulate matter smaller than 2.5 μm (PM2.5) as an indicator of ETS. We measured the indoor PM2.5 concentrations at 20 internet cafes, 20 pubs, and 20 pool halls using Sidepak AM510, a direct reading portable real time monitor, from October to December 2015. Smoking was observed in 65% of internet cafes, 10% of pubs, and 85% of pool halls. The average of PM2.5 concentration was 98.2 μg/m3, 29.0 μg/m3, and 134.2 μg/m3 at internet cafes, pubs, and pool halls, respectively. PM2.5 concentrations in internet cafes and pool halls were 2 to 2.7 times higher than the 24 hour exposure standard for outdoor PM2.5 (50 μg/m3) of the Ministry of the Environment. Although a smoking ban had been implemented at internet cafes and pubs, smoking is still taking place in those places. More stringent legal action are required for the success of legal action to protect patrons and workers from second-hand smoke exposure. The ban on smoking in pool halls should be introduced as soon as
大学校园周围网吧、酒吧和台球厅的ets暴露特征
本研究的目的是确定室内环境烟草烟雾(ETS)水平,并通过测量小于2.5 μm的颗粒物(PM2.5)作为ETS的指标,评估大学校园周围接待场所无烟法的执行率。2015年10月至12月,我们使用Sidepak AM510(一种直读便携式实时监测仪)测量了20家网吧、20家酒吧和20家台球厅的室内PM2.5浓度。65%的网吧、10%的酒吧和85%的台球厅被发现吸烟。网吧、酒吧和台球厅的PM2.5平均浓度分别为98.2 μg/m3、29.0 μg/m3和134.2 μg/m3。网吧和台球厅的PM2.5浓度比环境部规定的室外24小时暴露标准(50 μg/m3)高出2 ~ 2.7倍。尽管网吧和酒吧已经实施了禁烟令,但在这些地方仍有人吸烟。保护顾客和工人免受二手烟危害的法律行动要取得成功,就需要采取更严格的法律行动。台球厅禁烟令应尽快实施
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信