{"title":"Hankel Matrix Based Algorithm for Cardiac Pulse Wave Base and Peak Lines Correction","authors":"Andrei Krivošei, M. Min, P. Annus, Olev Märtens, M. Metshein, Kristina Lotamõis, M. Rist","doi":"10.1109/MeMeA54994.2022.9856564","DOIUrl":null,"url":null,"abstract":"In the paper we proposed a new method for the cardiac pulse wave base lines and peak lines estimation and correction. The proposed method is mainly directed, but not limited, to the Electrical Bio-Impedance (EBI) and Central Aortic Pressure (CAP) signals. However, the method can be extended to other signal kinds and application fields. Definitely, the proposed method can be applied to the PPG signals and blood pressure waveforms measured from different body locations, not only central aortic pressure. The base line correction approach, instead of filtering, is selected due to the physiological peculiarities of the cardiac cycle. The minimum value of a cardiac signal, which is the diastolic blood pressure (minimum pressure in the cardiac cycle), varies much less than the systolic peak value. Thus, in our research work we use the base line correction (subtraction) instead of mean value subtraction (filtering) to get cardiac signal's component. The proposed method is based on combination of the mathematical morphology and on the Hankel matrix. The method does not need separate estimates of peaks and valleys of the waveforms. Moreover, for correctly estimated signal frequency, the proposed method estimates the base line and the peak line as a piecewise lines between signal's minima or maxima. The result is a corrected cardiac signal that does not need additional processing, based on piecewise estimates of the base and peak lines.","PeriodicalId":106228,"journal":{"name":"2022 IEEE International Symposium on Medical Measurements and Applications (MeMeA)","volume":"4 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-06-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE International Symposium on Medical Measurements and Applications (MeMeA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MeMeA54994.2022.9856564","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

In the paper we proposed a new method for the cardiac pulse wave base lines and peak lines estimation and correction. The proposed method is mainly directed, but not limited, to the Electrical Bio-Impedance (EBI) and Central Aortic Pressure (CAP) signals. However, the method can be extended to other signal kinds and application fields. Definitely, the proposed method can be applied to the PPG signals and blood pressure waveforms measured from different body locations, not only central aortic pressure. The base line correction approach, instead of filtering, is selected due to the physiological peculiarities of the cardiac cycle. The minimum value of a cardiac signal, which is the diastolic blood pressure (minimum pressure in the cardiac cycle), varies much less than the systolic peak value. Thus, in our research work we use the base line correction (subtraction) instead of mean value subtraction (filtering) to get cardiac signal's component. The proposed method is based on combination of the mathematical morphology and on the Hankel matrix. The method does not need separate estimates of peaks and valleys of the waveforms. Moreover, for correctly estimated signal frequency, the proposed method estimates the base line and the peak line as a piecewise lines between signal's minima or maxima. The result is a corrected cardiac signal that does not need additional processing, based on piecewise estimates of the base and peak lines.
基于Hankel矩阵的心脏脉搏波基和峰值线校正算法
本文提出了一种心脏脉搏波基线和峰值线估计与校正的新方法。该方法主要针对但不限于电生物阻抗(EBI)和中央主动脉压(CAP)信号。然而,该方法可以推广到其他信号类型和应用领域。当然,所提出的方法可以应用于不同身体部位的PPG信号和血压波形,而不仅仅是中央主动脉压。由于心脏周期的生理特性,选择基线校正方法而不是滤波方法。心脏信号的最小值,即舒张压(心脏周期中的最小压力),变化远小于收缩峰值。因此,在我们的研究工作中,我们使用基线校正(减法)而不是平均值减法(滤波)来获得心脏信号的成分。该方法基于数学形态学和汉克尔矩阵的结合。该方法不需要单独估计波形的波峰和波谷。此外,对于正确估计的信号频率,该方法将基线和峰值线估计为信号最小值或最大值之间的分段线。结果是一个校正的心脏信号,不需要额外的处理,基于基线和峰线的分段估计。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信