Hand Function Kinematics when using a Simulated Myoelectric Prosthesis

Heather E. Williams, Quinn A. Boser, P. Pilarski, Craig S. Chapman, A. Vette, Jacqueline S. Hebert
{"title":"Hand Function Kinematics when using a Simulated Myoelectric Prosthesis","authors":"Heather E. Williams, Quinn A. Boser, P. Pilarski, Craig S. Chapman, A. Vette, Jacqueline S. Hebert","doi":"10.1109/ICORR.2019.8779443","DOIUrl":null,"url":null,"abstract":"Studies that investigate myoelectric prosthesis control commonly use non-disabled participants fitted with a simulated prosthetic device. This approach improves participant recruitment numbers but assumes that simulated movements represent those of actual prosthesis users. If this assumption is valid, then movement performance differences between simulated prosthesis users and normative populations should be similar to differences between actual prosthesis users and normative populations. As a first step in testing this assumption, the objective of this study was to quantify movement performance differences between simulated transradial myoelectric prosthesis hand function and normative hand function. Motion capture technology was used to obtain hand kinematics for 12 non-disabled simulated prosthesis participants who performed a functional object-manipulation task. Performance metrics, end effector movement, and grip aperture results were compared to 20 nondisabled participants who used their own hand during task execution. Simulated prosthesis users were expected to perform the functional task more slowly, with multiple peaks in end effector velocity profiles, and a plateau in grip aperture when reaching to pick up objects, when compared to non-disabled participants. This study confirmed these expectations and recommends that subsequent research be undertaken to quantify differences in actual myoelectric prosthesis hand function versus normative hand function.","PeriodicalId":130415,"journal":{"name":"2019 IEEE 16th International Conference on Rehabilitation Robotics (ICORR)","volume":"137 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE 16th International Conference on Rehabilitation Robotics (ICORR)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICORR.2019.8779443","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

Abstract

Studies that investigate myoelectric prosthesis control commonly use non-disabled participants fitted with a simulated prosthetic device. This approach improves participant recruitment numbers but assumes that simulated movements represent those of actual prosthesis users. If this assumption is valid, then movement performance differences between simulated prosthesis users and normative populations should be similar to differences between actual prosthesis users and normative populations. As a first step in testing this assumption, the objective of this study was to quantify movement performance differences between simulated transradial myoelectric prosthesis hand function and normative hand function. Motion capture technology was used to obtain hand kinematics for 12 non-disabled simulated prosthesis participants who performed a functional object-manipulation task. Performance metrics, end effector movement, and grip aperture results were compared to 20 nondisabled participants who used their own hand during task execution. Simulated prosthesis users were expected to perform the functional task more slowly, with multiple peaks in end effector velocity profiles, and a plateau in grip aperture when reaching to pick up objects, when compared to non-disabled participants. This study confirmed these expectations and recommends that subsequent research be undertaken to quantify differences in actual myoelectric prosthesis hand function versus normative hand function.
使用模拟肌电假体时的手部功能运动学
研究肌电假体控制的研究通常使用配备模拟假体装置的非残疾参与者。这种方法提高了参与者的招募数量,但假设模拟的动作代表了实际假肢使用者的动作。如果这个假设是有效的,那么模拟假肢使用者和规范人群之间的运动性能差异应该类似于实际假肢使用者和规范人群之间的差异。作为验证这一假设的第一步,本研究的目的是量化模拟经桡骨肌电假肢手功能和正常手功能之间的运动表现差异。采用运动捕捉技术获得12名非残疾模拟假体参与者执行功能性物体操作任务的手部运动学。性能指标、末端执行器运动和握力孔径结果与20名在任务执行过程中使用自己的手的非残疾参与者进行了比较。与非残疾参与者相比,模拟假肢使用者执行功能性任务的速度更慢,在末端执行器速度曲线上有多个峰值,在抓取物体时抓手孔径平稳。该研究证实了这些预期,并建议进行后续研究,以量化实际肌电假肢手功能与规范手功能的差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信