Performance assessment of a pupil tracking system for adaptive optics retinal imaging

B. Sahin, F. Harms, Barbara Lamory
{"title":"Performance assessment of a pupil tracking system for adaptive optics retinal imaging","authors":"B. Sahin, F. Harms, Barbara Lamory","doi":"10.1117/12.814854","DOIUrl":null,"url":null,"abstract":"Adaptive Optics (AO) is particularly suitable for correction of aberrations that change over time - a necessity for high resolution imaging of the retina. The rapidly changing aberrations originating from eye movements require wavefront sensors (WFS) with high repetition rates. Our approach is enhancing aberration correction by integrating a Pupil Tracking System (PTS) into the AO loop of the retinal imaging system. In this study we assessed the performance of the PTS developed for this purpose. Tests have demonstrated that the device achieves an accuracy of <15 μm in a ±2 mm range of eye movements with a standard deviation <10 μm. PTS can tolerate ±5 mm defocus with an increase of 4 μm in mean standard deviation. In vivo measurements done with temporarily paralyzed pupils have resulted in a precision of approximately 13 μm.","PeriodicalId":184459,"journal":{"name":"Canterbury Workshop and School in Optical Coherence Tomography and Adaptive Optics","volume":"71 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-05-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Canterbury Workshop and School in Optical Coherence Tomography and Adaptive Optics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.814854","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Adaptive Optics (AO) is particularly suitable for correction of aberrations that change over time - a necessity for high resolution imaging of the retina. The rapidly changing aberrations originating from eye movements require wavefront sensors (WFS) with high repetition rates. Our approach is enhancing aberration correction by integrating a Pupil Tracking System (PTS) into the AO loop of the retinal imaging system. In this study we assessed the performance of the PTS developed for this purpose. Tests have demonstrated that the device achieves an accuracy of <15 μm in a ±2 mm range of eye movements with a standard deviation <10 μm. PTS can tolerate ±5 mm defocus with an increase of 4 μm in mean standard deviation. In vivo measurements done with temporarily paralyzed pupils have resulted in a precision of approximately 13 μm.
自适应光学视网膜成像瞳孔跟踪系统的性能评估
自适应光学(AO)特别适合于校正随时间变化的像差,这是视网膜高分辨率成像的必要条件。眼球运动引起的快速变化的像差需要高重复率的波前传感器。我们的方法是通过将瞳孔跟踪系统(PTS)集成到视网膜成像系统的AO回路中来增强像差校正。在本研究中,我们评估了为此目的开发的PTS的性能。测试表明,该设备在±2mm的眼球运动范围内实现了<15 μm的精度,标准差<10 μm。PTS可以容忍±5mm的离焦,平均标准差增加4 μm。对暂时瘫痪的瞳孔进行体内测量,其精度约为13 μm。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信