{"title":"Performance assessment of a pupil tracking system for adaptive optics retinal imaging","authors":"B. Sahin, F. Harms, Barbara Lamory","doi":"10.1117/12.814854","DOIUrl":null,"url":null,"abstract":"Adaptive Optics (AO) is particularly suitable for correction of aberrations that change over time - a necessity for high resolution imaging of the retina. The rapidly changing aberrations originating from eye movements require wavefront sensors (WFS) with high repetition rates. Our approach is enhancing aberration correction by integrating a Pupil Tracking System (PTS) into the AO loop of the retinal imaging system. In this study we assessed the performance of the PTS developed for this purpose. Tests have demonstrated that the device achieves an accuracy of <15 μm in a ±2 mm range of eye movements with a standard deviation <10 μm. PTS can tolerate ±5 mm defocus with an increase of 4 μm in mean standard deviation. In vivo measurements done with temporarily paralyzed pupils have resulted in a precision of approximately 13 μm.","PeriodicalId":184459,"journal":{"name":"Canterbury Workshop and School in Optical Coherence Tomography and Adaptive Optics","volume":"71 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-05-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Canterbury Workshop and School in Optical Coherence Tomography and Adaptive Optics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.814854","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
Abstract
Adaptive Optics (AO) is particularly suitable for correction of aberrations that change over time - a necessity for high resolution imaging of the retina. The rapidly changing aberrations originating from eye movements require wavefront sensors (WFS) with high repetition rates. Our approach is enhancing aberration correction by integrating a Pupil Tracking System (PTS) into the AO loop of the retinal imaging system. In this study we assessed the performance of the PTS developed for this purpose. Tests have demonstrated that the device achieves an accuracy of <15 μm in a ±2 mm range of eye movements with a standard deviation <10 μm. PTS can tolerate ±5 mm defocus with an increase of 4 μm in mean standard deviation. In vivo measurements done with temporarily paralyzed pupils have resulted in a precision of approximately 13 μm.