A multi-level inverter configuration for 4n pole induction motor drive by using conventional two-level inverters

A. Rao, N. K. Kumar, K. Sivakumar
{"title":"A multi-level inverter configuration for 4n pole induction motor drive by using conventional two-level inverters","authors":"A. Rao, N. K. Kumar, K. Sivakumar","doi":"10.1109/ICIT.2015.7125163","DOIUrl":null,"url":null,"abstract":"A multi-level inverter configuration for 4n pole induction motor drive is presented in this paper. This topology is developed using three two-level inverters and two isolated dc sources. Among these three two-level inverters one inverter is switched at fundamental frequency and remaining two inverters are switched at higher frequency. Two isolated dc sources with equal magnitude are used in this topology to block the path for zero sequence currents. Low frequency operated inverter is connected to one dc source and high frequency operated inverters are connected to other dc source. The magnitude of dc source voltage required in this topology is four times lesser than the dc source required in conventional five-level NPC inverter configuration. The first center band harmonics are cancelled by providing 1800 phase shift between the high frequency carrier signals. This topology can be operated during the failure of any one inverter switches or any one dc source which will increase the reliability of the system. The number of switching devices used in this configuration is considerably less compared to conventional five-level inverters. This configuration is best suitable for high power applications where low frequency operated inverter can use thyristors as switching devices. The proposed topology is simulated in MATLAB/Simulink with (5HP) four pole induction motor and results are presented to show the validity of this configuration.","PeriodicalId":156295,"journal":{"name":"2015 IEEE International Conference on Industrial Technology (ICIT)","volume":"15 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-03-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE International Conference on Industrial Technology (ICIT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICIT.2015.7125163","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11

Abstract

A multi-level inverter configuration for 4n pole induction motor drive is presented in this paper. This topology is developed using three two-level inverters and two isolated dc sources. Among these three two-level inverters one inverter is switched at fundamental frequency and remaining two inverters are switched at higher frequency. Two isolated dc sources with equal magnitude are used in this topology to block the path for zero sequence currents. Low frequency operated inverter is connected to one dc source and high frequency operated inverters are connected to other dc source. The magnitude of dc source voltage required in this topology is four times lesser than the dc source required in conventional five-level NPC inverter configuration. The first center band harmonics are cancelled by providing 1800 phase shift between the high frequency carrier signals. This topology can be operated during the failure of any one inverter switches or any one dc source which will increase the reliability of the system. The number of switching devices used in this configuration is considerably less compared to conventional five-level inverters. This configuration is best suitable for high power applications where low frequency operated inverter can use thyristors as switching devices. The proposed topology is simulated in MATLAB/Simulink with (5HP) four pole induction motor and results are presented to show the validity of this configuration.
采用传统的双电平逆变器驱动4n极感应电机的多级逆变器配置
本文提出了一种用于4n极感应电机驱动的多级逆变器结构。这种拓扑结构是使用三个双电平逆变器和两个隔离直流电源开发的。在这三个两电平逆变器中,一个逆变器以基频开关,其余两个逆变器以高频开关。在这种拓扑结构中,使用两个相等幅度的隔离直流源来阻断零序电流的路径。低频操作的逆变器连接到一个直流源,高频操作的逆变器连接到另一个直流源。在这种拓扑结构中所需的直流源电压的幅度比传统的五电平NPC逆变器配置中所需的直流源小四倍。通过在高频载波信号之间提供1800相移来消除第一中心频带谐波。这种拓扑可以在任何一个逆变器开关或任何一个直流电源故障期间运行,这将增加系统的可靠性。与传统的五电平逆变器相比,在这种配置中使用的开关设备数量要少得多。这种配置最适合高功率应用,其中低频操作的逆变器可以使用晶闸管作为开关器件。用(5HP)四极感应电动机在MATLAB/Simulink中对所提出的拓扑结构进行了仿真,结果表明了该结构的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信