{"title":"Solid-state breaker protection in MVDC systems","authors":"K. Corzine, Allan Overstreet, P.E. Tom Baragona","doi":"10.1109/ESTS.2017.8069315","DOIUrl":null,"url":null,"abstract":"The development of medium-voltage DC power distribution for future Naval ships brings questions about the protection methods to be used in various places within the architecture. This paper starts with overlaying the current-time curve of a solid-state DC breaker with a traditional DC breaker. Using both methods can address slowly encroaching faults and rapidly occurring faults. A medium-voltage DC system demonstrator is described which includes solid-state breaker protection. The system is tested in the laboratory where it is demonstrated that a hard fault can be isolated from a controlled rectifier by the solid-state breaker within the ultra-fast time period (sub-millisecond). With this system, faults of various time scales (slow, fast, and ultra-fast) can be addressed using traditional breakers, power electronic controls, and solid-state breakers.","PeriodicalId":227033,"journal":{"name":"2017 IEEE Electric Ship Technologies Symposium (ESTS)","volume":"13 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"13","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 IEEE Electric Ship Technologies Symposium (ESTS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ESTS.2017.8069315","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13
Abstract
The development of medium-voltage DC power distribution for future Naval ships brings questions about the protection methods to be used in various places within the architecture. This paper starts with overlaying the current-time curve of a solid-state DC breaker with a traditional DC breaker. Using both methods can address slowly encroaching faults and rapidly occurring faults. A medium-voltage DC system demonstrator is described which includes solid-state breaker protection. The system is tested in the laboratory where it is demonstrated that a hard fault can be isolated from a controlled rectifier by the solid-state breaker within the ultra-fast time period (sub-millisecond). With this system, faults of various time scales (slow, fast, and ultra-fast) can be addressed using traditional breakers, power electronic controls, and solid-state breakers.