Parametric electrical impedance tomography for monitoring bone mineral density in the spine using 3D human model

Neta Naimark, S. Abboud, M. Arad
{"title":"Parametric electrical impedance tomography for monitoring bone mineral density in the spine using 3D human model","authors":"Neta Naimark, S. Abboud, M. Arad","doi":"10.1504/IJMEI.2018.10013915","DOIUrl":null,"url":null,"abstract":"Monitoring methods of bone mineral density (BMD), the standard measure for osteoporosis diagnosis, are both costly and complex. Since changes in bone permittivity and conductivity values occur due to changes in BMD, they can be used as a simple and inexpensive tool for monitoring BMD. In this work the parametric electrical impedance tomography (pEIT) method for monitoring BMD in the spine using 3D human model is theoretically evaluated. Numerical solver on the forward problem in 3D is used for computing electric potential measured on body surface. Varied spinal BMD are simulated by varying bone relative permittivity and conductivity values which represent different disease stages. The inverse problem is solved by creating a lookup-table of different BMD values.","PeriodicalId":193362,"journal":{"name":"Int. J. Medical Eng. Informatics","volume":"11 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-07-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Int. J. Medical Eng. Informatics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1504/IJMEI.2018.10013915","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Monitoring methods of bone mineral density (BMD), the standard measure for osteoporosis diagnosis, are both costly and complex. Since changes in bone permittivity and conductivity values occur due to changes in BMD, they can be used as a simple and inexpensive tool for monitoring BMD. In this work the parametric electrical impedance tomography (pEIT) method for monitoring BMD in the spine using 3D human model is theoretically evaluated. Numerical solver on the forward problem in 3D is used for computing electric potential measured on body surface. Varied spinal BMD are simulated by varying bone relative permittivity and conductivity values which represent different disease stages. The inverse problem is solved by creating a lookup-table of different BMD values.
参数电阻抗断层扫描监测骨密度在脊柱使用三维人体模型
骨矿物质密度(BMD)是骨质疏松症诊断的标准指标,其监测方法既昂贵又复杂。由于骨介电常数和电导率值的变化是由于骨密度的变化而发生的,因此它们可以作为监测骨密度的简单而廉价的工具。在这项工作中,参数电阻抗断层扫描(pEIT)方法监测骨密度在脊柱使用三维人体模型的理论评估。利用三维正演问题的数值求解器计算体表测得的电势。通过改变代表不同疾病阶段的骨相对介电常数和电导率值来模拟不同的脊柱骨密度。通过创建不同BMD值的查询表来解决反问题。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信