Development of microfocus x-ray source based on CNT emitter for intraoperative specimen radiographic system

A. Gupta, S. Yeo, Jaekyu Jang, Jaeik Jung, Jinho Choi, Jong-Wook Lim, WooSeob Kim, Junyoung Park, H. Park, M. Chae, Y. Yeon, J. Ahn, Seung Hoon Kim, Namkug Kim, B. Ko, J. Ryu
{"title":"Development of microfocus x-ray source based on CNT emitter for intraoperative specimen radiographic system","authors":"A. Gupta, S. Yeo, Jaekyu Jang, Jaeik Jung, Jinho Choi, Jong-Wook Lim, WooSeob Kim, Junyoung Park, H. Park, M. Chae, Y. Yeon, J. Ahn, Seung Hoon Kim, Namkug Kim, B. Ko, J. Ryu","doi":"10.1117/12.2582087","DOIUrl":null,"url":null,"abstract":"A microfocus X-ray source based on carbon nanotube (CNT) emitter grown by chemical vapor deposition is presented in this paper. The microfocus X-ray source is developed for the intraoperative specimen radiographic system, which can be used inside the operation theatre and helps reducing the surgery time during breast conserving surgery by confirming the extent of margin on specimen. This high focusing X-ray source is realized by growing CNTs on pointed structures. The field emission characteristic shows that maximum anode current of 1mA, which corresponds to a maximum emission current density of 500 mA/cm2 from the CNT-based point emitter. The optimized parameter for the assembly of electron gun was achieved by using commercially available CST simulation software. Consequently, this microfocus X-ray tube could produce X-ray image of multilayer printed circuit board showing fine lines of integrated circuit.","PeriodicalId":199502,"journal":{"name":"Medical Imaging 2021: Physics of Medical Imaging","volume":"18 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-02-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Imaging 2021: Physics of Medical Imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2582087","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

A microfocus X-ray source based on carbon nanotube (CNT) emitter grown by chemical vapor deposition is presented in this paper. The microfocus X-ray source is developed for the intraoperative specimen radiographic system, which can be used inside the operation theatre and helps reducing the surgery time during breast conserving surgery by confirming the extent of margin on specimen. This high focusing X-ray source is realized by growing CNTs on pointed structures. The field emission characteristic shows that maximum anode current of 1mA, which corresponds to a maximum emission current density of 500 mA/cm2 from the CNT-based point emitter. The optimized parameter for the assembly of electron gun was achieved by using commercially available CST simulation software. Consequently, this microfocus X-ray tube could produce X-ray image of multilayer printed circuit board showing fine lines of integrated circuit.
术中标本照相系统中基于CNT发射器的微聚焦x射线源的研制
提出了一种基于化学气相沉积法生长的碳纳米管发射极的微聚焦x射线源。微聚焦x射线源是为术中标本造影系统而开发的,可在手术室内使用,在保乳手术中通过确认标本边缘的程度,减少手术时间。这种高聚焦x射线源是通过在尖结构上生长碳纳米管来实现的。场发射特性表明,最大阳极电流为1mA,对应于基于cnt的点发射极的最大发射电流密度为500 mA/cm2。利用市售的CST仿真软件对电子枪装配参数进行了优化。因此,该微聚焦x射线管可以产生多层印刷电路板的x射线图像,显示集成电路的细线。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信