Evaluation and implementation of a system to eliminate arbitrary load effects in current-based monitoring of induction machines

R. R. Schoen, T. Habetler
{"title":"Evaluation and implementation of a system to eliminate arbitrary load effects in current-based monitoring of induction machines","authors":"R. R. Schoen, T. Habetler","doi":"10.1109/IAS.1996.557108","DOIUrl":null,"url":null,"abstract":"This paper presents a method for removing the load effects from the monitored quantity of the machine. Fault conditions in induction machines cause the magnetic field in the air gap of the machine to be nonuniform. This results in harmonics in the stator current of the motor which can be measured in order to determine the health of the motor. However, variations in the load torque which are not related to the health of the machine typically have exactly the same effect on the load current. Previously presented schemes for current-based condition monitoring ignore the load effect or assume it is known. Therefore, a scheme for determining machine health in the presence of a varying load torque requires some method for separating the two effects. This is accomplished by comparing the actual stator current to a model reference value which includes the load effects. The difference between these two signals provides a filtered quantity, independent of variations of the load, that allows continuous on-line condition monitoring to be conducted without concern for the load condition. Simulation and test results illustrate the effects on the spectrum of the monitored quantity for both constant and eccentric air gaps when in the presence of an oscillating load.","PeriodicalId":177291,"journal":{"name":"IAS '96. Conference Record of the 1996 IEEE Industry Applications Conference Thirty-First IAS Annual Meeting","volume":"47 8 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1996-10-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"169","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IAS '96. Conference Record of the 1996 IEEE Industry Applications Conference Thirty-First IAS Annual Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IAS.1996.557108","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 169

Abstract

This paper presents a method for removing the load effects from the monitored quantity of the machine. Fault conditions in induction machines cause the magnetic field in the air gap of the machine to be nonuniform. This results in harmonics in the stator current of the motor which can be measured in order to determine the health of the motor. However, variations in the load torque which are not related to the health of the machine typically have exactly the same effect on the load current. Previously presented schemes for current-based condition monitoring ignore the load effect or assume it is known. Therefore, a scheme for determining machine health in the presence of a varying load torque requires some method for separating the two effects. This is accomplished by comparing the actual stator current to a model reference value which includes the load effects. The difference between these two signals provides a filtered quantity, independent of variations of the load, that allows continuous on-line condition monitoring to be conducted without concern for the load condition. Simulation and test results illustrate the effects on the spectrum of the monitored quantity for both constant and eccentric air gaps when in the presence of an oscillating load.
感应电机电流监测中消除任意负载影响系统的评估与实现
本文提出了一种从机器监测量中去除负荷影响的方法。感应电机的故障条件导致电机气隙中的磁场不均匀。这会导致电机定子电流中的谐波,可以通过测量来确定电机的健康状况。然而,与机器的健康无关的负载转矩的变化通常对负载电流有完全相同的影响。以前提出的基于电流的状态监测方案忽略了负载效应或假设它是已知的。因此,在负载转矩变化的情况下,确定机器健康状况的方案需要一些方法来分离这两种影响。这是通过将实际定子电流与包含负载影响的模型参考值进行比较来实现的。这两个信号之间的差异提供了一个独立于负载变化的滤波量,允许在不关心负载状况的情况下进行连续在线状态监测。仿真和试验结果说明了当存在振荡负载时,恒定气隙和偏心气隙对监测量频谱的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信