Load frequency control of multi-microgrid using energy storage system

A. Chowdhury, Md. Asaduz-Zaman
{"title":"Load frequency control of multi-microgrid using energy storage system","authors":"A. Chowdhury, Md. Asaduz-Zaman","doi":"10.1109/ICECE.2014.7026975","DOIUrl":null,"url":null,"abstract":"Control of active power and frequency in a power system is referred to as load frequency control (LFC). A linear combination of tie line power between interconnected system and frequency deviations, defined as area control error (ACE), is regulated to zero by LFC such that frequency and tie-line power errors are forced to zeros and a balance is achieved between generation and load. This paper presents an investigation on the LFC of multi-microgrid (MMG) using energy storage system (ESS). The tie-line connected MMG system consists of two microgrids, each made up of a synchronous generator, a PV source, a wind power system, ESS and load. Control strategies are developed based on both, frequency deviation and ACE, to regulate the ESS output. A performance index is defined for comparative assessment of control strategies. Effectiveness of the frequency control strategies is studied through simulation.","PeriodicalId":335492,"journal":{"name":"8th International Conference on Electrical and Computer Engineering","volume":"55 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"30","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"8th International Conference on Electrical and Computer Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICECE.2014.7026975","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 30

Abstract

Control of active power and frequency in a power system is referred to as load frequency control (LFC). A linear combination of tie line power between interconnected system and frequency deviations, defined as area control error (ACE), is regulated to zero by LFC such that frequency and tie-line power errors are forced to zeros and a balance is achieved between generation and load. This paper presents an investigation on the LFC of multi-microgrid (MMG) using energy storage system (ESS). The tie-line connected MMG system consists of two microgrids, each made up of a synchronous generator, a PV source, a wind power system, ESS and load. Control strategies are developed based on both, frequency deviation and ACE, to regulate the ESS output. A performance index is defined for comparative assessment of control strategies. Effectiveness of the frequency control strategies is studied through simulation.
基于储能系统的多微网负荷频率控制
在电力系统中对有功功率和频率的控制称为负荷频率控制(LFC)。连接系统之间的联络线功率与频率偏差的线性组合,定义为区域控制误差(ACE),由LFC调节为零,从而使频率和联络线功率误差强制为零,从而实现发电和负载之间的平衡。本文研究了基于储能系统(ESS)的多微电网LFC。联络线连接的MMG系统由两个微电网组成,每个微电网由同步发电机、光伏电源、风力发电系统、ESS和负载组成。基于频率偏差和ACE开发了控制策略,以调节ESS输出。定义了一个性能指标,用于比较评估控制策略。通过仿真研究了频率控制策略的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信