Quantification of Corticospinal Tract Atrophy Using Diffusion Tensor Imaging: A Potential Diagnostic Tool in Amyotrophic Lateral Sclerosis

M. A. Noureldine, Y. A. Daulei, R. Kikano, N. Riachi, Youssef Fares, R. Ahdab, A. Zaylaa
{"title":"Quantification of Corticospinal Tract Atrophy Using Diffusion Tensor Imaging: A Potential Diagnostic Tool in Amyotrophic Lateral Sclerosis","authors":"M. A. Noureldine, Y. A. Daulei, R. Kikano, N. Riachi, Youssef Fares, R. Ahdab, A. Zaylaa","doi":"10.1109/IMCET.2018.8603039","DOIUrl":null,"url":null,"abstract":"Amyotrophic Lateral Sclerosis is a rare neurode-generative disease affecting the motor tract pathways. The role of neuroimaging in diagnosing Amyotrophic Lateral Sclerosis is still growing, and no definite technique has been adopted yet. Using an advanced neuroimaging technique, namely Diffusion Tensor Imaging, we propose a novel non-invasive, objective and quantitative technique to help in the diagnosis of Amyotrophic Lateral Sclerosis. Specifically, we collected Fractional Anisotropy and Apparent Diffusion Coefficient measurements at three anatomical sites (Posterior Limb of the Internal Capsule, Anterior Cerebral Peduncle, and Pre-Pyramidal Decussation in the medulla oblongata), where Corticospinal Tracts cross inside the brain and brainstem, in 10 Amyotrophic Lateral Sclerosis patients and 10 healthy controls. Then, we derived Side-to-Side Ratios of the collected Fractional Anisotropy and Apparent Diffusion Coefficient data at every site, and statistically evaluated these data to check for differences between abnormal patients and controls. Our results showed that for Amyotrophic Lateral Sclerosis patients, the Apparent Diffusion Coefficient inter-side difference was $0.4500\\times 10^{-10}$, which was more than double the Apparent Diffusion Coefficient inter-side difference in Controls $(0.0212\\times 10^{-10})$. The Side-to-Side Ratio of Apparent Diffusion Coefficient at the Posterior Limb of the Internal Capsule was significantly different between abnormal patients and Controls. The Receiver Operating Characteristic curve comparing the Side-to-Side Ratio of Apparent Diffusion Coefficient at the Posterior Limb of the Internal Capsule between abnormal and Control groups showed a sensitivity and specificity of 30% and 90%, respectively, with a likelihood ratio of 3.0 for values <1.017. Our study appeared promising and is the first of its kind in terms of evaluating the diagnostic value of the Side-to-Side Ratios of Fractional Anisotropy and Apparent Diffusion Coefficient measurements at different levels of the central motor pathway in Amyotrophic Lateral Sclerosis patients.","PeriodicalId":220641,"journal":{"name":"2018 IEEE International Multidisciplinary Conference on Engineering Technology (IMCET)","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE International Multidisciplinary Conference on Engineering Technology (IMCET)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IMCET.2018.8603039","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Amyotrophic Lateral Sclerosis is a rare neurode-generative disease affecting the motor tract pathways. The role of neuroimaging in diagnosing Amyotrophic Lateral Sclerosis is still growing, and no definite technique has been adopted yet. Using an advanced neuroimaging technique, namely Diffusion Tensor Imaging, we propose a novel non-invasive, objective and quantitative technique to help in the diagnosis of Amyotrophic Lateral Sclerosis. Specifically, we collected Fractional Anisotropy and Apparent Diffusion Coefficient measurements at three anatomical sites (Posterior Limb of the Internal Capsule, Anterior Cerebral Peduncle, and Pre-Pyramidal Decussation in the medulla oblongata), where Corticospinal Tracts cross inside the brain and brainstem, in 10 Amyotrophic Lateral Sclerosis patients and 10 healthy controls. Then, we derived Side-to-Side Ratios of the collected Fractional Anisotropy and Apparent Diffusion Coefficient data at every site, and statistically evaluated these data to check for differences between abnormal patients and controls. Our results showed that for Amyotrophic Lateral Sclerosis patients, the Apparent Diffusion Coefficient inter-side difference was $0.4500\times 10^{-10}$, which was more than double the Apparent Diffusion Coefficient inter-side difference in Controls $(0.0212\times 10^{-10})$. The Side-to-Side Ratio of Apparent Diffusion Coefficient at the Posterior Limb of the Internal Capsule was significantly different between abnormal patients and Controls. The Receiver Operating Characteristic curve comparing the Side-to-Side Ratio of Apparent Diffusion Coefficient at the Posterior Limb of the Internal Capsule between abnormal and Control groups showed a sensitivity and specificity of 30% and 90%, respectively, with a likelihood ratio of 3.0 for values <1.017. Our study appeared promising and is the first of its kind in terms of evaluating the diagnostic value of the Side-to-Side Ratios of Fractional Anisotropy and Apparent Diffusion Coefficient measurements at different levels of the central motor pathway in Amyotrophic Lateral Sclerosis patients.
使用弥散张量成像定量皮质脊髓束萎缩:肌萎缩侧索硬化的潜在诊断工具
肌萎缩侧索硬化症是一种罕见的影响运动道的神经退行性疾病。神经影像学在肌萎缩性侧索硬化症诊断中的作用仍在增长,尚未采用明确的技术。利用先进的神经成像技术,即弥散张量成像,我们提出了一种新的无创、客观和定量的技术来帮助诊断肌萎缩性侧索硬化症。具体来说,我们收集了10名肌萎缩性侧索硬化症患者和10名健康对照者在大脑和脑干内皮质脊髓束交叉的三个解剖部位(内囊后肢、脑前脚和延髓锥体前交叉)的分数各向异性和表观扩散系数测量值。然后,我们得到每个部位收集的分数各向异性和表观扩散系数数据的侧对侧比,并对这些数据进行统计评估,以检查异常患者与对照组之间的差异。结果表明,肌萎缩性侧索硬化症患者的表观扩散系数侧间差值为0.4500\ × 10^{-10}$,是对照组(0.0212\ × 10^{-10})$的两倍多。异常组与对照组内囊后肢表观扩散系数的左右比差异有统计学意义。对比异常组与对照组内囊后肢表观扩散系数左右比的受试者工作特征曲线,敏感性为30%,特异性为90%,似然比为3.0,值<1.017。我们的研究看起来很有希望,并且是同类研究中第一个评估在肌萎缩性侧索硬化症患者不同水平中央运动通路的分数各向异性的侧对侧比和表观扩散系数测量的诊断价值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信