PENERAPAN METODE ADAPTIVE MEDIAN FILTER UNTUK MEREDUKSI NOISE PADA CITRA X-RAY

Wika Pratiwi, Fince Tinus Waruwu
{"title":"PENERAPAN METODE ADAPTIVE MEDIAN FILTER UNTUK MEREDUKSI NOISE PADA CITRA X-RAY","authors":"Wika Pratiwi, Fince Tinus Waruwu","doi":"10.30865/KOMIK.V2I1.917","DOIUrl":null,"url":null,"abstract":"The problem often faced by radiologists in analyzing thorax fractures through manual x-ray images and requiring a longer time to study the image and radiologists also often have difficulty reading x-ray images that have noise when shooting x-ray and can lead to difficulties in diagnosis. The adaptive median filter method is a suitable problem-solving technique. In the improvement of the quality of the x-ray image, the x-ray image must first be converted into the pixel image value, to get the pixel value from the x-ray image. -ray then determine the matrix value to get the maximum, minimum, median and pixel coordinate values. Then determine whether the pixel value will be replaced with a median value, if not noise then the pixel value is not replaced. The end result of this system is in the form of design in reducing noise on x-ray imagery which is used as an aid in analyzing x-ray images. This system will help radiologists in reading images.Keywords: X-ray image, noise reduction, adaptive median filter","PeriodicalId":246167,"journal":{"name":"KOMIK (Konferensi Nasional Teknologi Informasi dan Komputer)","volume":"8 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-10-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"KOMIK (Konferensi Nasional Teknologi Informasi dan Komputer)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.30865/KOMIK.V2I1.917","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The problem often faced by radiologists in analyzing thorax fractures through manual x-ray images and requiring a longer time to study the image and radiologists also often have difficulty reading x-ray images that have noise when shooting x-ray and can lead to difficulties in diagnosis. The adaptive median filter method is a suitable problem-solving technique. In the improvement of the quality of the x-ray image, the x-ray image must first be converted into the pixel image value, to get the pixel value from the x-ray image. -ray then determine the matrix value to get the maximum, minimum, median and pixel coordinate values. Then determine whether the pixel value will be replaced with a median value, if not noise then the pixel value is not replaced. The end result of this system is in the form of design in reducing noise on x-ray imagery which is used as an aid in analyzing x-ray images. This system will help radiologists in reading images.Keywords: X-ray image, noise reduction, adaptive median filter
采用经上位元滤镜方法对x光图像进行还原噪声
放射科医师在通过手工x线图像分析胸部骨折时经常面临的问题,需要较长的时间来研究图像,并且放射科医师在拍摄x线时也经常难以读取有噪声的x线图像,从而导致诊断困难。自适应中值滤波方法是一种合适的求解方法。在提高x射线图像质量时,必须首先将x射线图像转换为像素图像值,才能从x射线图像中得到像素值。-ray然后确定矩阵值,得到最大值、最小值、中值和像素的坐标值。然后确定像素值是否将被替换为中值,如果不是噪声则不替换像素值。该系统的最终结果是以降低x射线图像噪声的设计形式,用于辅助分析x射线图像。这个系统将帮助放射科医生阅读图像。关键词:x射线图像,降噪,自适应中值滤波
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信