Dentin thickness of the mesio-buccal root wall of the lower first molar using cone beam computerized tomography (CBCT)

Aleksandra Djeri, Irena Radman-Kuzmanović, Nikola Moravac, Milan Tejic, Renata Josipović, Adriana Arbutina, Saša Marin, N. Trtić, V. Veselinović
{"title":"Dentin thickness of the mesio-buccal root wall of the lower first molar using cone beam computerized tomography (CBCT)","authors":"Aleksandra Djeri, Irena Radman-Kuzmanović, Nikola Moravac, Milan Tejic, Renata Josipović, Adriana Arbutina, Saša Marin, N. Trtić, V. Veselinović","doi":"10.2298/sgs2302071d","DOIUrl":null,"url":null,"abstract":"Introduction. The aim of this work was to check the average thickness of\n dentinal wall of the mesio-buccal root of the first lower molar using CBCT\n axial sections of intact teeth. Material and method. In this cross-sectional\n study, 100 CBCT images of mandibular first molars from the Promax 3Dent\n radiology center in Banja Luka, Bosnia and Herzegovina were evaluated. A\n Planmeca Promax3D Max apparatus (Planmeca, Helsinki, Finland) was used, with\n a field of view (FOV) of 8 ? 8 cm and a resolution of 0.1 mm. Analysis was\n performed using Romexis Viewer software version 3.1.1 (Planmeca, Helsinki,\n Finland). At an axial thickness of 0.1 mm, transverse sections with a\n distance of 1 mm were made below the furcation area (at a magnification ?10)\n at a distance of 1, 2, 3, 4, 5 mm from the furcation. The data were then\n analyzed by paired t-test. Results. The thickness of dentinal wall of the\n mesio-buccal root of the lower first molar was significantly smaller at 2 mm\n and 3 mm than when measured at 1, 4 and 5 mm (p < 0.05). There was no\n significant difference between measurements at 1, 4 and 5 mm below the\n furcation area (p = 0.001). Conclusion. Due to the small thickness of\n dentinal wall at 2-3 mm below the furcation in the root canal, caution is\n required when instrumenting mesio-buccal canal of the lower first molar and\n correct selection of the instrumentation technique in order to avoid\n transportation or stripping perforation that may lead to root fracture.","PeriodicalId":180624,"journal":{"name":"Serbian Dental Journal","volume":"51 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Serbian Dental Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2298/sgs2302071d","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction. The aim of this work was to check the average thickness of dentinal wall of the mesio-buccal root of the first lower molar using CBCT axial sections of intact teeth. Material and method. In this cross-sectional study, 100 CBCT images of mandibular first molars from the Promax 3Dent radiology center in Banja Luka, Bosnia and Herzegovina were evaluated. A Planmeca Promax3D Max apparatus (Planmeca, Helsinki, Finland) was used, with a field of view (FOV) of 8 ? 8 cm and a resolution of 0.1 mm. Analysis was performed using Romexis Viewer software version 3.1.1 (Planmeca, Helsinki, Finland). At an axial thickness of 0.1 mm, transverse sections with a distance of 1 mm were made below the furcation area (at a magnification ?10) at a distance of 1, 2, 3, 4, 5 mm from the furcation. The data were then analyzed by paired t-test. Results. The thickness of dentinal wall of the mesio-buccal root of the lower first molar was significantly smaller at 2 mm and 3 mm than when measured at 1, 4 and 5 mm (p < 0.05). There was no significant difference between measurements at 1, 4 and 5 mm below the furcation area (p = 0.001). Conclusion. Due to the small thickness of dentinal wall at 2-3 mm below the furcation in the root canal, caution is required when instrumenting mesio-buccal canal of the lower first molar and correct selection of the instrumentation technique in order to avoid transportation or stripping perforation that may lead to root fracture.
锥形束计算机断层扫描(CBCT)对下第一磨牙中颊根壁牙本质厚度的研究
介绍。本研究的目的是利用完整牙的CBCT轴向切片检查第一下磨牙中颊根牙本质壁的平均厚度。材料和方法。在这项横断面研究中,对来自波斯尼亚和黑塞哥维那Banja Luka Promax 3Dent放射中心的下颌第一磨牙的100张CBCT图像进行了评估。使用Planmeca Promax3D Max设备(Planmeca,赫尔辛基,芬兰),视场(FOV)为8 ?8厘米,分辨率为0.1毫米。采用Romexis Viewer 3.1.1版软件(Planmeca, Helsinki, Finland)进行分析。在轴向厚度为0.1 mm时,在距离分叉1、2、3、4、5 mm处,在分叉区域下方(放大倍率为?10)做距离为1 mm的横切面。采用配对t检验对数据进行分析。结果。下第一磨牙中颊根牙管壁厚度在2、3 mm处明显小于1、4、5 mm处(p < 0.05)。在分叉区以下1,4,5 mm处的测量结果无显著差异(p = 0.001)。结论。由于根管分叉下2 ~ 3 mm的牙管壁厚度较小,在进行下第一磨牙中颊管内固定时要谨慎,正确选择固定技术,避免运输或剥离穿孔导致根管断裂。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信