Maximum Variation of Asynchronous Generation in Power System Based on Rotational Inertia and Frequency Response

S. Nuchprayoon
{"title":"Maximum Variation of Asynchronous Generation in Power System Based on Rotational Inertia and Frequency Response","authors":"S. Nuchprayoon","doi":"10.1109/SPIES48661.2020.9243090","DOIUrl":null,"url":null,"abstract":"This work describes the effect of increasing penetration of asynchronous generation on rotational inertia and frequency response of power system. It is shown that the both system inertia and frequency bias tend to be lower, as the penetration level is higher. Higher variations of frequency are of concern. It is proposed to determine the maximum allowable variation of asynchronous generation, without violating a constraint of frequency deviation. The maximum variation, not the penetration, can be assessed from quantifying system inertia and frequency bias after integrating asynchronous generation into power system. The assessment method is explained and discussed by using an illustrative example.","PeriodicalId":244426,"journal":{"name":"2020 2nd International Conference on Smart Power & Internet Energy Systems (SPIES)","volume":"22 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-09-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 2nd International Conference on Smart Power & Internet Energy Systems (SPIES)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SPIES48661.2020.9243090","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This work describes the effect of increasing penetration of asynchronous generation on rotational inertia and frequency response of power system. It is shown that the both system inertia and frequency bias tend to be lower, as the penetration level is higher. Higher variations of frequency are of concern. It is proposed to determine the maximum allowable variation of asynchronous generation, without violating a constraint of frequency deviation. The maximum variation, not the penetration, can be assessed from quantifying system inertia and frequency bias after integrating asynchronous generation into power system. The assessment method is explained and discussed by using an illustrative example.
基于转动惯量和频率响应的电力系统异步发电的最大变化
本文描述了增加异步发电渗透对电力系统转动惯量和频率响应的影响。结果表明,随着侵彻水平的提高,系统惯性和频率偏差都趋于降低。较高的频率变化值得关注。提出在不违反频率偏差约束的情况下,确定异步发电的最大允许变化。在异步发电并入电力系统后,可以通过量化系统惯性和频率偏差来评估最大变化,而不是渗透。通过实例对评价方法进行了说明和讨论。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信