Measurements of the distributed cavity phase shift in the LNE-SYRTE FO2 fountain

J. Guéna, S. Bize, A. Clairon, R. Li, K. Gibble
{"title":"Measurements of the distributed cavity phase shift in the LNE-SYRTE FO2 fountain","authors":"J. Guéna, S. Bize, A. Clairon, R. Li, K. Gibble","doi":"10.1109/FREQ.2010.5556321","DOIUrl":null,"url":null,"abstract":"We report measurements and calculations of distributed cavity phase errors in an atomic fountain clock. We isolate even and odd symmetry contributions to the distributed cavity phase shift and measure their characteristic power dependences. The measurements and model largely agree with no free parameters. Verification of the model\\ will enable a reduction of the distributed cavity phase uncertainty for current clocks and validates new cavity designs that have minimal phase variations.","PeriodicalId":344989,"journal":{"name":"2010 IEEE International Frequency Control Symposium","volume":"35 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 IEEE International Frequency Control Symposium","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/FREQ.2010.5556321","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

We report measurements and calculations of distributed cavity phase errors in an atomic fountain clock. We isolate even and odd symmetry contributions to the distributed cavity phase shift and measure their characteristic power dependences. The measurements and model largely agree with no free parameters. Verification of the model\ will enable a reduction of the distributed cavity phase uncertainty for current clocks and validates new cavity designs that have minimal phase variations.
lne - syte FO2喷泉分布腔相移的测量
本文报道了原子喷泉钟中分布腔相位误差的测量和计算。我们分离了奇偶对称对分布腔相移的贡献,并测量了它们的特征功率依赖性。在没有自由参数的情况下,测量结果和模型基本一致。模型的验证将能够减少当前时钟的分布式腔相位不确定性,并验证具有最小相位变化的新腔设计。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信