[Polarographic analysis of cobalt in biological specimens].

N A Soldatenkova, E K Ordzhonikidze, L L Prilutskaia
{"title":"[Polarographic analysis of cobalt in biological specimens].","authors":"N A Soldatenkova,&nbsp;E K Ordzhonikidze,&nbsp;L L Prilutskaia","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>References to different methods of cobalt detection in biologic material are given. Polarographic detection of cobalt in human urine and animal biologic material worked out by authors was used for evaluation of biologic MAC. Biologic material was limed by nitric and sulfuric acids. Sulfuric acid was carefully distilled off the burnt material. Mineralized material was dissolved in 10 ml of 1N hydrochloric acid, filtered and again steamed into moist salts. 2.5 ml of water, 0.5 ml of dimethylglyoxime (0.02 M), 2 ml of Na4P2O7 (0.2 M) and 5 ml of buffer solution (0.1 M NH4Cl and NH4OH) were added to limed mineral, than pH was driven to 9 by 1 = 2 drops of ammonia solution and after blowing through, the specimen was exposed to polarography in alternating current. ++Redox potential of cobalt is 1.18 V. The method can be used for detection of cobalt in urine of workers contacting with the stated metal. Sensitivity of the method is 0.02 Mkg/ml.</p>","PeriodicalId":12679,"journal":{"name":"Gigiena truda i professional'nye zabolevaniia","volume":" 6","pages":"40-1"},"PeriodicalIF":0.0000,"publicationDate":"1992-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Gigiena truda i professional'nye zabolevaniia","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

References to different methods of cobalt detection in biologic material are given. Polarographic detection of cobalt in human urine and animal biologic material worked out by authors was used for evaluation of biologic MAC. Biologic material was limed by nitric and sulfuric acids. Sulfuric acid was carefully distilled off the burnt material. Mineralized material was dissolved in 10 ml of 1N hydrochloric acid, filtered and again steamed into moist salts. 2.5 ml of water, 0.5 ml of dimethylglyoxime (0.02 M), 2 ml of Na4P2O7 (0.2 M) and 5 ml of buffer solution (0.1 M NH4Cl and NH4OH) were added to limed mineral, than pH was driven to 9 by 1 = 2 drops of ammonia solution and after blowing through, the specimen was exposed to polarography in alternating current. ++Redox potential of cobalt is 1.18 V. The method can be used for detection of cobalt in urine of workers contacting with the stated metal. Sensitivity of the method is 0.02 Mkg/ml.

[生物标本中钴的极谱分析]。
介绍了生物材料中钴的各种检测方法。用笔者编制的人尿和动物生物材料中钴的极谱法测定生物MAC,生物材料用硝酸和硫酸进行石灰化处理。硫酸被小心地从烧焦的物质中蒸馏出来。矿化物质溶解于10ml 1N盐酸中,过滤后再次蒸成湿盐。石灰矿中加入2.5 ml水、0.5 ml二甲基乙肟(0.02 M)、2 ml Na4P2O7 (0.2 M)和5 ml缓冲溶液(0.1 M NH4Cl和NH4OH),用1 = 2滴氨溶液将pH值驱动至9,吹过后,交变极谱法。钴的氧化还原电位为1.18 V。该方法可用于与所述金属接触的工人尿液中钴的检测。方法灵敏度为0.02 mg /ml。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信