Planar transformers with no common mode noise generation for flyback and forward converters

Mohammad Ali Saket, M. Ordonez, N. Shafiei
{"title":"Planar transformers with no common mode noise generation for flyback and forward converters","authors":"Mohammad Ali Saket, M. Ordonez, N. Shafiei","doi":"10.1109/APEC.2017.7930695","DOIUrl":null,"url":null,"abstract":"Flyback and Forward converters are two commonly used topologies for isolated low power applications. In order to enhance the performance of these converters, planar transformers (PT) can be used that feature lower height, considerably lower leakage inductance, excellent thermal characteristics, repeatability, and manufacturing simplicity. Selecting a proper winding arrangement for PT is a significant challenge, in particular given the large capacitances involved in flat structures. While interleaved structures significantly reduce the AC resistance and leakage inductance of PTs, they also lead to very large inter-winding capacitance, which produces significant levels of undesired common-mode (CM) noise that causes EMI problems. This paper focuses on the creation of interleaved winding structures that minimize CM noise and EMI commonly present in PT and at the same time achieves low AC resistance and leakage inductance. The experimental results show that the proposed PTs not only have very low AC resistance and leakage inductance, but also generate extremely low levels of CM noise. Considering that the proposed PT has inter-winding capacitance equal to 700pF, it is very interesting to see that it generates significantly less CM noise than does a traditional wire-wound transformer that has only 10pF parasitic capacitance. Therefore, the proposed method gives designers the opportunity to minimize AC resistance and leakage inductance by using highly inter-leaved structures, without having to worry about CM noise caused by large inter-winding capacitance.","PeriodicalId":201289,"journal":{"name":"2017 IEEE Applied Power Electronics Conference and Exposition (APEC)","volume":"21 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-03-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 IEEE Applied Power Electronics Conference and Exposition (APEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APEC.2017.7930695","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

Flyback and Forward converters are two commonly used topologies for isolated low power applications. In order to enhance the performance of these converters, planar transformers (PT) can be used that feature lower height, considerably lower leakage inductance, excellent thermal characteristics, repeatability, and manufacturing simplicity. Selecting a proper winding arrangement for PT is a significant challenge, in particular given the large capacitances involved in flat structures. While interleaved structures significantly reduce the AC resistance and leakage inductance of PTs, they also lead to very large inter-winding capacitance, which produces significant levels of undesired common-mode (CM) noise that causes EMI problems. This paper focuses on the creation of interleaved winding structures that minimize CM noise and EMI commonly present in PT and at the same time achieves low AC resistance and leakage inductance. The experimental results show that the proposed PTs not only have very low AC resistance and leakage inductance, but also generate extremely low levels of CM noise. Considering that the proposed PT has inter-winding capacitance equal to 700pF, it is very interesting to see that it generates significantly less CM noise than does a traditional wire-wound transformer that has only 10pF parasitic capacitance. Therefore, the proposed method gives designers the opportunity to minimize AC resistance and leakage inductance by using highly inter-leaved structures, without having to worry about CM noise caused by large inter-winding capacitance.
用于反激变换器和正激变换器的无共模噪声产生的平面变压器
反激变换器和正激变换器是隔离型低功率应用中常用的两种拓扑结构。为了提高这些变换器的性能,可以使用具有较低高度、相当低的漏感、优异的热特性、可重复性和制造简单性的平面变压器(PT)。为PT选择合适的绕组排列是一个重大挑战,特别是考虑到扁平结构所涉及的大电容。虽然交错结构显著降低了pt的交流电阻和漏感,但它们也会导致非常大的绕组间电容,从而产生大量不希望的共模(CM)噪声,从而导致EMI问题。本文的重点是创建交错绕组结构,以尽量减少CM噪声和电磁干扰通常存在于PT,同时实现低交流电阻和漏感。实验结果表明,所提出的PTs不仅具有非常低的交流电阻和漏感,而且产生极低的CM噪声。考虑到所提出的PT具有等于700pF的绕组间电容,非常有趣的是,它产生的CM噪声明显低于只有10pF寄生电容的传统线绕变压器。因此,所提出的方法使设计人员有机会通过使用高度交错的结构来最小化交流电阻和漏感,而不必担心大的绕组间电容引起的CM噪声。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信