INTERPRETASI LAPISAN BAWAH PERMUKAAN DENGAN MENGGUNAKAN METODE GEOLISTRIK KONFIGURASI SCHLUMBERGER DAN GEOKIMIA: STUDI KASUS TPA MUARA FAJAR RUMBAI

Alifia Putri Yasmin, M. Juandi
{"title":"INTERPRETASI LAPISAN BAWAH PERMUKAAN DENGAN MENGGUNAKAN METODE GEOLISTRIK KONFIGURASI SCHLUMBERGER DAN GEOKIMIA: STUDI KASUS TPA MUARA FAJAR RUMBAI","authors":"Alifia Putri Yasmin, M. Juandi","doi":"10.31258/JKFI.18.1.22-28","DOIUrl":null,"url":null,"abstract":"The need for water daily is a big problem for people living around Muara Fajar Final Processing Place (TPA) – Rumbai. This study aims to identify the depth of subsurface structures around the Muara Fajar landfill area using the Schlumberger configuration dielectric method and determine the water quality in the community wells around the landfill site. The data obtained in the acquisition process are used to calculate the apparent resistivity value at each measurement point and analyzed quantitatively and qualitatively. Then proceed with the inversion process using the progress program so that obtained resistivity value and layer thickness at each point of measurement. The results of measurement inline 1 get a range of resistivity values ranging from 961.19 – 2.10 Ωm and line 2 of 109.31 – 31.15 Ωm. Underground water taken is residents well water in the research area as many as 5 sample points using GPS. This underground water sample will be tested with parameters such as pH, TDS, Conductivity, Salinity, and Turbidity. Underground water cannot be consumed from the results of the water quality test with the parameters mentioned at the beginning if referring to the Regulation of the Minister of Health of the Republic of Indonesia because the pH obtained in all underground water samples is < 6.5 or acidic, the value of the conductivity exceeds the quality standard, and high dominant salinity value. As for the TDS and Turbidity parameters, the values are by the quality standard.","PeriodicalId":403286,"journal":{"name":"Komunikasi Fisika Indonesia","volume":"11 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-03-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Komunikasi Fisika Indonesia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31258/JKFI.18.1.22-28","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The need for water daily is a big problem for people living around Muara Fajar Final Processing Place (TPA) – Rumbai. This study aims to identify the depth of subsurface structures around the Muara Fajar landfill area using the Schlumberger configuration dielectric method and determine the water quality in the community wells around the landfill site. The data obtained in the acquisition process are used to calculate the apparent resistivity value at each measurement point and analyzed quantitatively and qualitatively. Then proceed with the inversion process using the progress program so that obtained resistivity value and layer thickness at each point of measurement. The results of measurement inline 1 get a range of resistivity values ranging from 961.19 – 2.10 Ωm and line 2 of 109.31 – 31.15 Ωm. Underground water taken is residents well water in the research area as many as 5 sample points using GPS. This underground water sample will be tested with parameters such as pH, TDS, Conductivity, Salinity, and Turbidity. Underground water cannot be consumed from the results of the water quality test with the parameters mentioned at the beginning if referring to the Regulation of the Minister of Health of the Republic of Indonesia because the pH obtained in all underground water samples is < 6.5 or acidic, the value of the conductivity exceeds the quality standard, and high dominant salinity value. As for the TDS and Turbidity parameters, the values are by the quality standard.
表层解释使用斯伦贝谢和地化学排气管的方法:研究黎明流苏口TPA病例
对于生活在Muara Fajar最终处理中心(TPA)附近的人们来说,每天对水的需求是一个大问题。本研究旨在利用斯伦贝谢配置介电法确定Muara Fajar垃圾填埋场周围地下结构的深度,并确定垃圾填埋场周围社区井的水质。利用采集过程中获得的数据计算各测点的视电阻率值,并进行定量定性分析。然后利用进度程序进行反演,得到各测点的电阻率值和层厚。线1的测量结果得到的电阻率值范围为961.19 - 2.10 Ωm,线2的测量结果为109.31 - 31.15 Ωm。利用GPS采集的地下水为研究区内多达5个样点的居民井水。该地下水样品将进行参数测试,如pH值,TDS,电导率,盐度和浊度。参照印度尼西亚共和国卫生部长条例,由于所有地下水样品的pH值均< 6.5或呈酸性,电导率值超过质量标准,且优势盐度值较高,因此不能从开始所述参数的水质检测结果中饮用地下水。TDS和浊度参数均按质量标准计算。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信