Evaluation of Hydropower Equivalents Parameters Over Time

Pandu Prianto, Evelin Blom, L. Söder
{"title":"Evaluation of Hydropower Equivalents Parameters Over Time","authors":"Pandu Prianto, Evelin Blom, L. Söder","doi":"10.1109/icgea54406.2022.9791993","DOIUrl":null,"url":null,"abstract":"Actual hydropower systems often contain complex river systems, making simulations of hydropower systems computationally extensive. With the help of an Equivalent model, which is an artificial simpler hydropower system, the computational issue can be avoided. The Equivalent model aims to imitate the actual hydropower system, hence can be used for studies of large power systems with faster computational time. In this paper, different Equivalent models of hydropower systems in different periods and trading areas in Sweden have been computed, which are then evaluated and validated by comparing the hourly relative power generation difference. The relative power difference is 4.89% – 19.36%, depending on the period and trading area. Different Equivalent model performance over time indicates that the Equivalent parameters should change over time. By dividing a year appropriately, a well performing Equivalent can be obtained, which is shown by the Equivalent with low relative power difference.","PeriodicalId":151236,"journal":{"name":"2022 6th International Conference on Green Energy and Applications (ICGEA)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-03-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 6th International Conference on Green Energy and Applications (ICGEA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/icgea54406.2022.9791993","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Actual hydropower systems often contain complex river systems, making simulations of hydropower systems computationally extensive. With the help of an Equivalent model, which is an artificial simpler hydropower system, the computational issue can be avoided. The Equivalent model aims to imitate the actual hydropower system, hence can be used for studies of large power systems with faster computational time. In this paper, different Equivalent models of hydropower systems in different periods and trading areas in Sweden have been computed, which are then evaluated and validated by comparing the hourly relative power generation difference. The relative power difference is 4.89% – 19.36%, depending on the period and trading area. Different Equivalent model performance over time indicates that the Equivalent parameters should change over time. By dividing a year appropriately, a well performing Equivalent can be obtained, which is shown by the Equivalent with low relative power difference.
水电当量参数随时间的评估
实际的水电系统往往包含复杂的河流系统,使得水电系统的模拟计算量很大。利用人工简化的水力系统等效模型,可以避免计算问题。等效模型旨在模拟实际的水电系统,因此可以用于计算时间更快的大型电力系统的研究。本文计算了瑞典不同时段、不同交易区水电系统的不同等效模型,并通过比较小时相对发电量差对模型进行了评价和验证。根据时间段和交易区域的不同,相对权力差异为4.89% - 19.36%。随时间变化的等效模型性能不同表明等效参数应随时间变化。将一年适当地划分,可以得到性能良好的等效,其表现为相对功率差较小的等效。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信