Verification of multiband system for noncontact emissivity measurements

A. Mazikowski
{"title":"Verification of multiband system for noncontact emissivity measurements","authors":"A. Mazikowski","doi":"10.1117/12.721028","DOIUrl":null,"url":null,"abstract":"In recent years an increasing interest in passive multiband systems for temperature and emissivity measurement was noted. However, available literature about passive multiband systems concentrated exclusively on problem of temperature measurements with these systems in situation when these systems can be also used for non-contact emissivity measurements. Modeling of such systems, what is usually the first stage of system designing, requires acceptation of several simplifications and approximations. In this paper an experimental verification of modeling results is performed based on developed measurement setup. Obtained results are in good agreement with results of previously performed computer analyses that shows usefulness of multiband method for emissivity measurements in working conditions.","PeriodicalId":405495,"journal":{"name":"Optoelectronic and Electronic Sensors","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-10-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Optoelectronic and Electronic Sensors","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.721028","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In recent years an increasing interest in passive multiband systems for temperature and emissivity measurement was noted. However, available literature about passive multiband systems concentrated exclusively on problem of temperature measurements with these systems in situation when these systems can be also used for non-contact emissivity measurements. Modeling of such systems, what is usually the first stage of system designing, requires acceptation of several simplifications and approximations. In this paper an experimental verification of modeling results is performed based on developed measurement setup. Obtained results are in good agreement with results of previously performed computer analyses that shows usefulness of multiband method for emissivity measurements in working conditions.
非接触发射率测量的多波段系统验证
近年来,人们对温度和发射率测量的无源多波段系统越来越感兴趣。然而,关于无源多波段系统的现有文献只集中在这些系统的温度测量问题上,而这些系统也可以用于非接触发射率测量。这类系统的建模通常是系统设计的第一阶段,需要接受一些简化和近似。本文基于研制的测量装置对建模结果进行了实验验证。所得结果与先前进行的计算机分析结果一致,显示了多波段方法在工作条件下发射率测量的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信