{"title":"Improvements of cardiopulmonary monitoring using harmonic six-port radar system","authors":"L. Chioukh, T. Djerafi, D. Deslandes, K. Wu","doi":"10.1109/GSMM.2015.7175465","DOIUrl":null,"url":null,"abstract":"A new bio-radar based on a harmonic six-port junction is proposed to improve the performances of monitoring vital sign systems. The amplitude of heart beat compared to the higher harmonics of breathing and the intermodulation product are the main factors influencing the accuracy of the detection. Simulation-based performance demonstrate the advantage of the novel method using the harmonic six-port discriminator for detection. It has been shown that harmonic six-port radar can meet requirements of monitoring vital sign by cancelling breathing harmonic and intermodulation. Experimental results using the proposed platform at 12 GHz and 24 GHz on patient proved the validity and feasibility of cardiopulmonary estimation using harmonic diversity six-port sensor.","PeriodicalId":405509,"journal":{"name":"Global Symposium on Millimeter-Waves (GSMM)","volume":"78 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-05-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Global Symposium on Millimeter-Waves (GSMM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/GSMM.2015.7175465","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

A new bio-radar based on a harmonic six-port junction is proposed to improve the performances of monitoring vital sign systems. The amplitude of heart beat compared to the higher harmonics of breathing and the intermodulation product are the main factors influencing the accuracy of the detection. Simulation-based performance demonstrate the advantage of the novel method using the harmonic six-port discriminator for detection. It has been shown that harmonic six-port radar can meet requirements of monitoring vital sign by cancelling breathing harmonic and intermodulation. Experimental results using the proposed platform at 12 GHz and 24 GHz on patient proved the validity and feasibility of cardiopulmonary estimation using harmonic diversity six-port sensor.
谐波六端口雷达系统心肺监测的改进
为了提高生命体征监测系统的性能,提出了一种基于谐波六端口结的新型生物雷达。影响检测精度的主要因素是心跳相对于呼吸高次谐波的幅值和互调积。基于仿真的性能验证了采用谐波六端口鉴别器进行检测的新方法的优越性。研究表明,谐波六口雷达通过消除呼吸谐波和互调,可以满足生命体征监测的要求。实验结果表明,该平台在12 GHz和24 GHz频段对患者进行心肺功能估计的有效性和可行性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信