Ersin Çintesun, Mete Berti̇zli̇oğlu, Mete Ateş, Abdullah Güler, Çetin Çelik
{"title":"Gebelerde proteinüri tanısında kullanılan yöntemlerin karşılaştırılması","authors":"Ersin Çintesun, Mete Berti̇zli̇oğlu, Mete Ateş, Abdullah Güler, Çetin Çelik","doi":"10.15321/geneltipder.2021.296","DOIUrl":null,"url":null,"abstract":"Objective: The aim of this study was to compare the total protein content in 24 hours urine with dipstic, protein / creatinine (P / K) ratio in spot urine in our pregnant women who were diagnosed with preeclampsia. Material and Methods: In this study, 317 patients who underwent dipstick method, P / K ratio and total protein analysis in 24-hour urine were included in the study with a prediagnosis of preeclampsia at a university hospital gynecology and obstetrics clinic between January 2016 and December 2018. These three values of patients were compared with each other. Results: When the total proteinuria threshold in the 24-hour urine was 300 mg / day, the P-C ratio cut-off value was 0.34 mg protein / mg creatinine, the sensitivity was 68.9% and the specificity was 78.7%. A moderate, significant correlation was observed between total urinary P / K ratio and total proteinuria in 24-h urine (r= 0.629 p <0.001). Conclusion: It can be used as an alternative test in the 24-hour urine total protein test of P / C ratio in spot urine in emergencies where there is not enough time for 24 hour total urine analysis.","PeriodicalId":139503,"journal":{"name":"Genel Tip Dergisi","volume":"25 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Genel Tip Dergisi","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15321/geneltipder.2021.296","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: The aim of this study was to compare the total protein content in 24 hours urine with dipstic, protein / creatinine (P / K) ratio in spot urine in our pregnant women who were diagnosed with preeclampsia. Material and Methods: In this study, 317 patients who underwent dipstick method, P / K ratio and total protein analysis in 24-hour urine were included in the study with a prediagnosis of preeclampsia at a university hospital gynecology and obstetrics clinic between January 2016 and December 2018. These three values of patients were compared with each other. Results: When the total proteinuria threshold in the 24-hour urine was 300 mg / day, the P-C ratio cut-off value was 0.34 mg protein / mg creatinine, the sensitivity was 68.9% and the specificity was 78.7%. A moderate, significant correlation was observed between total urinary P / K ratio and total proteinuria in 24-h urine (r= 0.629 p <0.001). Conclusion: It can be used as an alternative test in the 24-hour urine total protein test of P / C ratio in spot urine in emergencies where there is not enough time for 24 hour total urine analysis.