VERIFICATION OF THE GEOMETRY OF SAMPLES FOR THE STUDY OF TRABECULAR BONE STRUCTURES

A. Cichański, K. Nowicki
{"title":"VERIFICATION OF THE GEOMETRY OF SAMPLES FOR THE STUDY OF TRABECULAR BONE STRUCTURES","authors":"A. Cichański, K. Nowicki","doi":"10.21495/5896-3-106","DOIUrl":null,"url":null,"abstract":": Indicators of trabecular bone structure along with the apparent Young's modulus may be a predictor of the risk of bone fracture in the elderly. The use of mechanical treatment in the process of obtaining a sample of a structure to determine these indicators causes damage to its surface, leading to defects in the shape and position of the outline. The paper presents the results of studies leading to the demonstration of the influence of these defects on the values of the BV/TV and the apparent Young's modulus. These results justify the necessity to select the theoretical shape of a cylinder from the scanned images in order to define the geometrical shape of a representative sample. The paper presents a method for determining the parameters of this cylinder based on the best-fit cylinder algorithm.","PeriodicalId":383836,"journal":{"name":"Engineering Mechanics 2020","volume":"23 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Engineering Mechanics 2020","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21495/5896-3-106","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

: Indicators of trabecular bone structure along with the apparent Young's modulus may be a predictor of the risk of bone fracture in the elderly. The use of mechanical treatment in the process of obtaining a sample of a structure to determine these indicators causes damage to its surface, leading to defects in the shape and position of the outline. The paper presents the results of studies leading to the demonstration of the influence of these defects on the values of the BV/TV and the apparent Young's modulus. These results justify the necessity to select the theoretical shape of a cylinder from the scanned images in order to define the geometrical shape of a representative sample. The paper presents a method for determining the parameters of this cylinder based on the best-fit cylinder algorithm.
小梁骨结构研究样品的几何验证
骨小梁结构指标以及表观杨氏模量可能是老年人骨折风险的预测指标。利用机械处理的方法在获得一个结构样品的过程中确定这些指标会对其表面造成损伤,从而导致轮廓形状和位置上的缺陷。本文给出了这些缺陷对BV/TV值和表观杨氏模量影响的研究结果。这些结果证明有必要从扫描图像中选择圆柱体的理论形状,以便确定代表性样品的几何形状。本文提出了一种基于最佳拟合圆柱体算法确定该圆柱体参数的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信