{"title":"Simple switching control method changes power converter into a current source","authors":"C. Deisch","doi":"10.1109/PESC.1978.7072368","DOIUrl":null,"url":null,"abstract":"A switching converter with an LC output filter behaves as a loose-tolerance voltage-controlled current source if each switch closure is ended when switch current reaches an adjustable threshold. This converter is then combined with an external feedback to produce a precise output voltage. By generating a fixed voltage with a current source in this manner, the converter has many advantages including continuous protection of the switches, stable and equal load sharing when several converters are operated in parallel, inherent overload protection, automatic switch symmetry correction, and fast system response.","PeriodicalId":363671,"journal":{"name":"1978 IEEE Power Electronics Specialists Conference","volume":"8 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1978-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"302","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"1978 IEEE Power Electronics Specialists Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESC.1978.7072368","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 302
Abstract
A switching converter with an LC output filter behaves as a loose-tolerance voltage-controlled current source if each switch closure is ended when switch current reaches an adjustable threshold. This converter is then combined with an external feedback to produce a precise output voltage. By generating a fixed voltage with a current source in this manner, the converter has many advantages including continuous protection of the switches, stable and equal load sharing when several converters are operated in parallel, inherent overload protection, automatic switch symmetry correction, and fast system response.