An assessment of bactericidal effect of two different types of lasers on enterococcus faecalis: An in vitro study

Mohammed Ahmeduddin, B. Nagesh, K. Reddy, K. Raj
{"title":"An assessment of bactericidal effect of two different types of lasers on enterococcus faecalis: An in vitro study","authors":"Mohammed Ahmeduddin, B. Nagesh, K. Reddy, K. Raj","doi":"10.4103/0976-2868.100975","DOIUrl":null,"url":null,"abstract":"Aim and Objective: To evaluate the bactericidal efficacy of the Nd:YAG laser and the Diode laser at different parameters to that of calcium hydroxide, and to know the effect of increase in lasing time on degree of disinfection. Materials and Methods: Fifty human single-rooted teeth were taken and were kept in 3% NaOCl for 15 mins and access cavities were prepared, the apical third of these roots was gradually enlarged until reaching the ISO 40- K file. Later the teeth were autoclaved and mounted on 2.5 ml eppendorf tubes filled with BHI medium which was autoclaved again. The teeth were inoculated with a standard strain of Enterococcus faecalis and incubated for one week. They were randomly divided into five groups and treated as follows, G-I: - Negative control. G-II:- 980 nm diode laser irradiation for five seconds and five cycles at 2W power, 10 Hz frequency and pulsed mode. G-III:- 980 nm diode laser irradiation for 10 seconds and five cycles at 2W power, 10 Hz frequency and pulsed mode. G-IV:- Nd:YAG laser irradiation for five seconds and five cycles at 2 W power, 15 Hz frequency and pulsed mode. G-V:- Nd:YAG laser irradiation for 10 seconds and five cycles at 2 W power, 15 Hz frequency and pulsed mode. The dentin dust was collected from superficial and deep dentin of coronal and apical halves of all the samples and CFU/ ml were evaluated after three days. Results: The results were calculated and statistical analysis was done using Kruskal Wallis ANOVA test by ranks and Mann Whitney's U test. Comparisons were done between the superficial and deep dentin of different groups and between the groups. Conclusion: Under the parameters of the samples tested Nd:YAG laser provided the best results for disinfection compared to Diode laser. However, both the Nd:YAG and Diode lasers provided clinically acceptable disinfection.","PeriodicalId":345720,"journal":{"name":"Journal of Dental Lasers","volume":"61 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Dental Lasers","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/0976-2868.100975","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

Aim and Objective: To evaluate the bactericidal efficacy of the Nd:YAG laser and the Diode laser at different parameters to that of calcium hydroxide, and to know the effect of increase in lasing time on degree of disinfection. Materials and Methods: Fifty human single-rooted teeth were taken and were kept in 3% NaOCl for 15 mins and access cavities were prepared, the apical third of these roots was gradually enlarged until reaching the ISO 40- K file. Later the teeth were autoclaved and mounted on 2.5 ml eppendorf tubes filled with BHI medium which was autoclaved again. The teeth were inoculated with a standard strain of Enterococcus faecalis and incubated for one week. They were randomly divided into five groups and treated as follows, G-I: - Negative control. G-II:- 980 nm diode laser irradiation for five seconds and five cycles at 2W power, 10 Hz frequency and pulsed mode. G-III:- 980 nm diode laser irradiation for 10 seconds and five cycles at 2W power, 10 Hz frequency and pulsed mode. G-IV:- Nd:YAG laser irradiation for five seconds and five cycles at 2 W power, 15 Hz frequency and pulsed mode. G-V:- Nd:YAG laser irradiation for 10 seconds and five cycles at 2 W power, 15 Hz frequency and pulsed mode. The dentin dust was collected from superficial and deep dentin of coronal and apical halves of all the samples and CFU/ ml were evaluated after three days. Results: The results were calculated and statistical analysis was done using Kruskal Wallis ANOVA test by ranks and Mann Whitney's U test. Comparisons were done between the superficial and deep dentin of different groups and between the groups. Conclusion: Under the parameters of the samples tested Nd:YAG laser provided the best results for disinfection compared to Diode laser. However, both the Nd:YAG and Diode lasers provided clinically acceptable disinfection.
两种不同类型激光对粪肠球菌杀菌效果的体外研究
目的与目的:评价不同参数下Nd:YAG激光器和二极管激光器对氢氧化钙激光器的杀菌效果,并了解激光照射时间的延长对消毒程度的影响。材料与方法:取50颗人单根牙,在3% NaOCl中保存15分钟,制备入路腔,逐渐扩大根尖的三分之一,直至达到ISO 40- K锉。随后,将牙齿进行高压灭菌,并安装在充满BHI培养基的2.5 ml附注管上,该附注管再次进行高压灭菌。用粪肠球菌标准菌株接种牙齿,孵育一周。随机分为5组,治疗方法如下:G-I组:-阴性对照组。G-II:- 980 nm二极管激光照射5秒,5个周期,2W功率,10hz频率,脉冲模式。G-III:- 980 nm二极管激光在2W功率,10hz频率和脉冲模式下照射10秒,5个周期。G-IV:- Nd:YAG激光在2w功率,15hz频率和脉冲模式下照射5秒,5个周期。G-V:- Nd:YAG激光在2w功率,15hz频率和脉冲模式下辐照10秒,5个周期。在所有样品的冠状和根尖各一半的牙本质表面和深层采集牙本质粉尘,3天后评估CFU/ ml。结果:采用Kruskal Wallis ANOVA检验和Mann Whitney’s U检验对结果进行计算和统计分析。比较不同组间及组间浅、深牙本质的差异。结论:在所测样品参数条件下,Nd:YAG激光消毒效果优于二极管激光。然而,Nd:YAG和二极管激光器都提供了临床可接受的消毒。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信