{"title":"Performance Analysis Smart-Shoes To Measure the Pulse in Dorsalis Pedis Artery","authors":"A. Aripriharta","doi":"10.52005/fidelity.v5i2.146","DOIUrl":null,"url":null,"abstract":"Wearable device has grown in popularity in recent years. This \narticle presents the performance of smart shoes as a biomedical \ndevice that can be used to capture heart rate signals from the \ndorsalis pedis artery on the leg. In general, heart rate is measured \nfrom the arteries located in the chest, hands, fingertips, and ears or \nneck. Even though the pulse from the dorsalis pedis has a smaller \namplitude compared to other arterial locations, the sensor is \nintegrated on smart shoes can catch the signal from the dorsalis \npedis pulse. Research is intended to analyze lifetime and accuracy \nsmart shoes. The experiment was carried out by 30 healthy male \nand female volunteers aged 20-25 years. The results obtained \nindicate that the sensor smart shoes can measure the dorsalis pedis \npulse and has an average error rate of 9.28% compared to a digital \nsphygmomanometer. Based on the results of energy consumption \nanalysis,smart shoes in this study has a lifetime of up to 25.86 hours \nusing a 1100 mAh battery.","PeriodicalId":359066,"journal":{"name":"FIDELITY : Jurnal Teknik Elektro","volume":"61 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-06-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"FIDELITY : Jurnal Teknik Elektro","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.52005/fidelity.v5i2.146","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Wearable device has grown in popularity in recent years. This
article presents the performance of smart shoes as a biomedical
device that can be used to capture heart rate signals from the
dorsalis pedis artery on the leg. In general, heart rate is measured
from the arteries located in the chest, hands, fingertips, and ears or
neck. Even though the pulse from the dorsalis pedis has a smaller
amplitude compared to other arterial locations, the sensor is
integrated on smart shoes can catch the signal from the dorsalis
pedis pulse. Research is intended to analyze lifetime and accuracy
smart shoes. The experiment was carried out by 30 healthy male
and female volunteers aged 20-25 years. The results obtained
indicate that the sensor smart shoes can measure the dorsalis pedis
pulse and has an average error rate of 9.28% compared to a digital
sphygmomanometer. Based on the results of energy consumption
analysis,smart shoes in this study has a lifetime of up to 25.86 hours
using a 1100 mAh battery.