Development of On-Line Partial Discharge Locator for Electric Power Cable

K. Yamashita, S. Watanuki, T. Miyake, T. Sakoda, Wataru Kawano
{"title":"Development of On-Line Partial Discharge Locator for Electric Power Cable","authors":"K. Yamashita, S. Watanuki, T. Miyake, T. Sakoda, Wataru Kawano","doi":"10.1109/EIC.2018.8481126","DOIUrl":null,"url":null,"abstract":"Although the demand of reliable power systems and stability of supplying electric power are quite crucial for all of power companies, aging and deterioration of the electric power equipment are ongoing. For this reason, we propose a partial discharge locator (PDL) system. This is possible to locate the cable fault for power cables under the transmission and the distribution systems in operation. In conventional systems, the propagation velocity of a PD pulse must be known for the cable fault detection. However, it likely depends on the deterioration state of the power cable. Thus, PDL uses injection signals only to measure the propagating time instead of obtaining propagation velocity. This implicates the need of communication among two devices in order to make system accurate. In this paper, we first show how the PDL works on-line power cable with time synchronization between two sides and injection trigger for obtaining propagating time. We also provide information of the propagation characteristics of a current pulse which simulates a partial discharge current on branched 22kV XLPE cables.","PeriodicalId":184139,"journal":{"name":"2018 IEEE Electrical Insulation Conference (EIC)","volume":"12 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE Electrical Insulation Conference (EIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EIC.2018.8481126","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

Although the demand of reliable power systems and stability of supplying electric power are quite crucial for all of power companies, aging and deterioration of the electric power equipment are ongoing. For this reason, we propose a partial discharge locator (PDL) system. This is possible to locate the cable fault for power cables under the transmission and the distribution systems in operation. In conventional systems, the propagation velocity of a PD pulse must be known for the cable fault detection. However, it likely depends on the deterioration state of the power cable. Thus, PDL uses injection signals only to measure the propagating time instead of obtaining propagation velocity. This implicates the need of communication among two devices in order to make system accurate. In this paper, we first show how the PDL works on-line power cable with time synchronization between two sides and injection trigger for obtaining propagating time. We also provide information of the propagation characteristics of a current pulse which simulates a partial discharge current on branched 22kV XLPE cables.
电力电缆局部放电在线定位仪的研制
虽然电力系统的可靠性和供电的稳定性对所有电力公司来说都是至关重要的,但电力设备的老化和劣化正在不断发生。为此,我们提出了局部放电定位系统(PDL)。这样可以对运行中的输配电系统下的电力电缆进行故障定位。在传统的系统中,为了进行电缆故障检测,必须知道PD脉冲的传播速度。然而,这可能取决于电力电缆的恶化状态。因此,PDL仅使用注入信号来测量传播时间,而不能获得传播速度。这意味着需要两个设备之间的通信,以使系统准确。在本文中,我们首先展示了PDL是如何工作在具有两侧时间同步和注入触发器的在线电力电缆中以获得传播时间。我们还提供了模拟分支22kV交联聚乙烯电缆上局部放电电流的电流脉冲传播特性的信息。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信