Space vector modulation techniques for current source rectifiers operating at switching frequencies up to 1 kHz

J. Espinoza, G. Joós, L.A. Cea, L. Salazar
{"title":"Space vector modulation techniques for current source rectifiers operating at switching frequencies up to 1 kHz","authors":"J. Espinoza, G. Joós, L.A. Cea, L. Salazar","doi":"10.1109/IECON.1998.724301","DOIUrl":null,"url":null,"abstract":"PWM current source rectifiers (PWM-CSRs) are gradually replacing phase-controlled thyristor-based rectifiers as front-end high power supplies. Advantages include reduced line current harmonic distortion and unity power factor operation. Moreover, with the help of regenerative and resonant snubbers, a three-phase six-switches bridge configuration can now control high power levels (1.2 MVA) while operating at switching frequencies up to 1 kHz. In this range of power and switching frequencies, the switching pattern must be carefully chosen since it defines the supply current harmonic distortion which finally restricts the maximum attainable total input power factor. This paper proposes two space vector based modulating techniques for high power/low switching frequency applications (<1 kHz). The developed switching patterns feature similar performance (low harmonic distortion, minimum switching frequency, and instantaneous line current control) to that obtained with optimum off-line pattern generators (such as selective harmonic elimination). Moreover, they add the following features: (a) the selection of the switches to turn-on/off and the calculation of their on/off-times are done by solving linear algebraic equations, (b) there is no need for stored data since calculations can be implemented on-line, (c) the overmodulation region is naturally covered, including six-step operation, and (d) the short circuit pulses are generated automatically and distributed symmetrically through all the power switches, which enables an even sharing of the switching and conduction losses.","PeriodicalId":377136,"journal":{"name":"IECON '98. Proceedings of the 24th Annual Conference of the IEEE Industrial Electronics Society (Cat. No.98CH36200)","volume":"188 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1998-08-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"12","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IECON '98. Proceedings of the 24th Annual Conference of the IEEE Industrial Electronics Society (Cat. No.98CH36200)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IECON.1998.724301","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 12

Abstract

PWM current source rectifiers (PWM-CSRs) are gradually replacing phase-controlled thyristor-based rectifiers as front-end high power supplies. Advantages include reduced line current harmonic distortion and unity power factor operation. Moreover, with the help of regenerative and resonant snubbers, a three-phase six-switches bridge configuration can now control high power levels (1.2 MVA) while operating at switching frequencies up to 1 kHz. In this range of power and switching frequencies, the switching pattern must be carefully chosen since it defines the supply current harmonic distortion which finally restricts the maximum attainable total input power factor. This paper proposes two space vector based modulating techniques for high power/low switching frequency applications (<1 kHz). The developed switching patterns feature similar performance (low harmonic distortion, minimum switching frequency, and instantaneous line current control) to that obtained with optimum off-line pattern generators (such as selective harmonic elimination). Moreover, they add the following features: (a) the selection of the switches to turn-on/off and the calculation of their on/off-times are done by solving linear algebraic equations, (b) there is no need for stored data since calculations can be implemented on-line, (c) the overmodulation region is naturally covered, including six-step operation, and (d) the short circuit pulses are generated automatically and distributed symmetrically through all the power switches, which enables an even sharing of the switching and conduction losses.
用于开关频率高达1khz的电流源整流器的空间矢量调制技术
PWM电流源整流器(PWM- csrs)正逐渐取代基于晶闸管的相控整流器作为前端大功率电源。优点是降低了线路电流谐波失真,工作功率因数统一。此外,在再生缓冲器和谐振缓冲器的帮助下,三相六开关桥配置现在可以控制高功率水平(1.2 MVA),同时工作在高达1 kHz的开关频率下。在这个功率和开关频率范围内,必须仔细选择开关模式,因为它决定了供电电流谐波失真,最终限制了可达到的最大总输入功率因数。本文提出了两种基于空间矢量的高功率/低开关频率(< 1khz)调制技术。所开发的开关模式具有与最佳离线模式发生器(如选择性谐波消除)相似的性能(低谐波失真、最小开关频率和瞬时线路电流控制)。此外,它们还增加了以下功能:(a)通过求解线性代数方程来选择开关的开/关和计算开关的开/关时间,(b)不需要存储数据,因为计算可以在线实现,(c)自然覆盖过调制区域,包括六步操作,(d)短路脉冲自动产生,并通过所有电源开关对称分布,这使得开关和传导损失均匀分担。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信